Solar case study · Nashville, Tennessee
32 solar panels and two EG4 batteries for a Nashville home
This case gives the solar system and standing-seam roof their own prices. That makes it easier to see what goes into the power system, what belongs to the roof, and what still depends on where the array will go.
- Panel nameplate total
- 13.6 kW DC
- Nominal battery capacity
- 28.6 kWh
- Solar and battery scope
- $60,820
What the solar system includes
Thirty-two 425-watt modules add up to 13.6 kW DC. The system pairs the array with an EG4 hybrid inverter and two batteries. The roof cost is separate from the solar equipment and installation.
| Component | Equipment or scope |
|---|---|
| Solar panels | 32 Jinko JKM425N-54HL4 modules, rated at 425 W each. |
| Hybrid inverter | EG4 FlexBOSS21. |
| Battery storage | Two EG4 PowerPro WallMount batteries at 14.3 kWh nominal each, 28.6 kWh nominal in total. |
| Separate metal roof | $49,400 for 26-gauge Ultra-Snap standing seam with a 1.75-inch seam and concealed clips. |
The array location is not specified. The solar scope allows for roof or ground mounting. The roof price does not establish that panels go on the new roof.
What the $60,820 solar line covers
The solar line covers the modules, inverter and storage as a system, along with the labor and equipment needed to connect and monitor it.
Physical mounting
Racking and bonding are included. The final mounting layout determines where those parts will go and how the roof or ground installation is detailed.
Electrical integration
The work includes connecting the solar equipment and batteries to the electrical system. This scope by itself does not tell you which individual circuits can run during an outage.
Monitoring and cleanup
Monitoring setup is included, together with cleanup. Ask how the monitoring app shows solar production, battery state and grid activity.
What to compare before deciding where the panels go
- Roof space and shade. Compare the usable roof planes with any available ground area. Trees, roof features and the need for service access can change the fit.
- The roof attachment detail. If the array goes on the roof, confirm which mounts suit that exact metal panel and how they interact with raised seams, edge metal and roof warranties.
- Backup loads and runtime. Battery nameplate capacity is a starting point. Confirm the circuits, expected demand and usable battery capacity before relying on a runtime estimate.
These numbers describe the equipment and the two separate scopes in this case. They are not an annual output estimate or a backup-runtime promise.