Solar Guide · The Solar Roofers
Short answer: A standard grid-tied rooftop solar installation will generally stop supplying your home when the utility goes down, even at noon on a clear day. The panels still receive sunlight; the system cannot just keep feeding power onto a dead utility line. Specially designed systems can isolate your home and supply selected loads directly from available sunshine without a battery. That's a different purchase from ordinary solar, and it won't give you power after sunset.
Prepared by The Solar Roofers. Company records report 500+ solar energy system installations and repairs in Tennessee, combined. Technical review is pending before publication.
In normal operation, a conventional grid-following inverter uses the utility as its reference. When that grid disappears, the inverter disconnects rather than continuing to energize a line crews may be working on. The Department of Energy calls this anti-islanding behavior. Backup operation requires a system designed to isolate a defined part of the home from the utility and safely provide power to it. Never try to bypass the system's shutdown or feed electricity backward through an outlet.
Enphase's U.S. Sunlight Backup technical brief is a useful example: a compatible grid-forming microinverter configuration works with a system controller and controlled loads. The same manufacturer's solar-only configuration does not provide backup just because it uses an IQ8 microinverter. Ask for the complete backup equipment list and backed-up circuits in the proposal. With no battery, a passing cloud or a motor starting can use up available output and cause some or all loads to drop.
Power in kW is how much can run at once; energy in kWh is how much can be supplied over time. A load averaging 500 watts for eight hours would use 4 kWh before losses. That's a made-up math example, not a runtime estimate for your home. A refrigerator, well pump, or HVAC compressor can also draw more at startup than it uses once running. A backup quote should account for both the expected energy and the largest loads that may start together.
Daylight-only backup can be reasonable if your goal is to run selected loads in good sun and interruptions are acceptable. If you want the refrigerator, lights, internet equipment, or another circuit to keep running overnight, discuss battery capacity, winter recharging and an approved generator option if needed. Don't assume a whole-home backup quote will run all electric heat, air conditioning, and EV charging at the same time. For health-critical equipment, don't assume a normal residential backup system is your only emergency plan.
Check the utility printed on your bill: Nashville Electric Service and Middle Tennessee Electric publish separate interconnection documents. NES tells customers to wait for approval before ordering system materials; MTE requires approval of its interconnection application and agreement before residential construction. Ask how your proposed backup equipment is represented in the application, and ask the installer to demonstrate the actual backup circuits at commissioning. A line in a quote that just says battery-ready does not tell you what will work during an outage today.
See how we compare rooftop, integrated and ground-mounted solar around Nashville. Compare home battery and backup options. See completed solar projects or request a roof-first solar assessment.
Sources and review: Prepared by The Solar Roofers. The sources above support the general guidance; they are not an engineering review of a specific roof or electrical system. See how we verify project figures and distinguish our observations from third-party guidance.
✦ Reviewed by The Solar Roofers Technical Team
Written and reviewed by the team that designs and installs our solar and battery systems, roofing Middle Tennessee since 2003. Licensed and insured · BBB A+ · Tesla Powerwall Certified Installer · TVA EnergyRight Preferred Partners Network · Reviewed October 2026