White Bluff, Tennessee · Site-specific unsigned proposal
A 6.375 kW White Bluff solar proposal with three EG4 batteries
This proposal specified 15 Jinko modules and 3 EG4 batteries for a White Bluff property. The quoted price was $44,155. The designer did not have the property's bills, so the financial and consumption forecasts used a 14,940 kWh placeholder, not the home's measured electrical use.
- 15 × 425 W solar modules
- 6.375 kW DC
- 3 × 14.3 kWh EG4 storage units
- 42.9 kWh nominal
- Proposed system cost, not a payment
- $44,155 quoted
What was included in the proposed system?
| Item | Proposed detail |
|---|---|
| Solar array | 15 JinkoSolar JKM425N-54HL4 N-type modules at 425 W each, 6.375 kW DC. One preliminary roof orientation, azimuth 77° and slope 29°. A site survey would confirm final layout. |
| Hybrid inverter | One EG4 FlexBOSS21. The quote lists 16 kW continuous output. Final load coverage or available export power was not established. |
| Battery storage | 3 EG4 PowerPro WallMount units at 14.3 kWh each, 42.9 kWh total by the equipment list. No usable backup duration or backed-up load schedule was established. |
| Racking and electrical | The proposal listed 26 black UFO-END-01-B1 end-fastening components, roof mounting and related electrical work through a licensed electrical partner. |
| Quoted price and work | $44,155 for the stated solar and battery scope, not a paid or signed sum. Roof repair or reinforcement and permit fees were not included unless specified. Permitting, utility coordination and final equipment locations still needed confirmation. |
The estimate describes separate equipment warranties and a two-year workmanship term for its roof-mounted work. The pricing document is not a signed warranty or an operating guarantee.
What did the model say about an east-facing array?
The proposal put fifteen modules on one face oriented roughly east. The table shows a higher modeled generation in late spring and summer than in winter. Three storage units say how much energy could be stored by nameplate, not how often the roof can charge them or how long they run any particular load.
| Month | Generation (kWh) | Assumed use (kWh) | Bill before | Bill after | Printed savings |
|---|---|---|---|---|---|
| Jan | 330 | 1,475 | $179 | $144 | $35 |
| Feb | 452 | 1,318 | $162 | $114 | $48 |
| Mar | 641 | 1,095 | $138 | $71 | $66 |
| Apr | 787 | 972 | $123 | $43 | $79 |
| May | 865 | 964 | $122 | $37 | $85 |
| Jun | 987 | 1,265 | $161 | $55 | $106 |
| Jul | 941 | 1,544 | $192 | $90 | $101 |
| Aug | 868 | 1,545 | $192 | $98 | $94 |
| Sep | 666 | 1,389 | $174 | $102 | $72 |
| Oct | 570 | 1,080 | $134 | $76 | $58 |
| Nov | 364 | 997 | $125 | $88 | $37 |
| Dec | 268 | 1,297 | $160 | $131 | $28 |
| Printed totals | 7,739 | 14,941 | $1,862 | $1,049 | $809 |
The summary forecast lists 7,740 kWh annual generation, while the monthly table prints 7,739 kWh. The summary's assumed use is 14,940 kWh, while the monthly table prints 14,941 kWh. The proposal's 52% modeled production-to-use figure depends on the placeholder and is not a bill-reduction rate or a measured result.
Why are there two different savings figures for year one?
The 12-month table prints $809 in estimated first-year savings. The separate 25-year projection starts at $556 in 2026. The two series are both shown as printed; the documents do not explain their difference well enough to present either as a reliable prediction.
| Model year | Annual savings | Cumulative net position |
|---|---|---|
| 2026 | $556 | −$43,599 |
| 2027 | $578 | −$43,021 |
| 2028 | $601 | −$42,420 |
| 2029 | $625 | −$41,795 |
| 2030 | $650 | −$41,145 |
| 2031 | $676 | −$40,469 |
| 2032 | $703 | −$39,766 |
| 2033 | $731 | −$39,035 |
| 2034 | $760 | −$38,275 |
| 2035 | $791 | −$37,484 |
| 2036 | $823 | −$36,661 |
| 2037 | $855 | −$35,806 |
| 2038 | $890 | −$34,916 |
| 2039 | $925 | −$33,991 |
| 2040 | $962 | −$33,029 |
| 2041 | $1,001 | −$32,028 |
| 2042 | $1,041 | −$30,987 |
| 2043 | $1,082 | −$29,905 |
| 2044 | $1,126 | −$28,779 |
| 2045 | $1,171 | −$27,608 |
| 2046 | $1,218 | −$26,391 |
| 2047 | $1,266 | −$25,125 |
| 2048 | $1,317 | −$23,808 |
| 2049 | $1,370 | −$22,438 |
| 2050 | $1,424 | −$21,014 |
The quote reports $23,141 in lifetime modeled bill savings and ends its separate cash-flow model at −$21,014. The source uses a 4% annual utility cost escalation, a 6.75% financial discount rate, and assumed energy and fixed charges of $0.11/kWh and $20.34/month. No account tariff or price path was verified.
System Advisor Model 2020.02.29.r2 is identified in the file; it lists 15.3% total system losses and 3.1% inverter loss. These are design inputs, not a field test. Model charts do not prove commissioning, output, battery performance, payoff or savings.
This was a site-specific, non-binding proposal. No executed contract, customer payment, permit or utility approval, installed-equipment photo, meter record or operating outcome was verified.
Start a solar quote with 12 months of actual use
Provide the full year of bills if possible, then identify the loads you want to keep running. A quote should distinguish the preliminary roof layout, the bill model and the battery-backup design.
Ask about a White Bluff solar designSource: Anonymized The Metal Roofers residential solar estimate, pp. 1–6. Monthly and annual projections reproduced separately. No customer data, roof aerial or equipment installation claimed.