Full design breakdown · Nashville residential proposal

14.08 kW of rooftop solar with three batteries

An actual proposal for a Nashville home, anonymized for comparison. The customer was quoted a grid-connected array and battery backup at a cash price. This example does not establish that the project went ahead, that the equipment was installed, or that actual bills matched the forecast.

$72,270Cash price quoted, before any separately billed fees.
14.08 kW DC32 rooftop panels at 440 W each.
42.9 kWhRated capacity across three batteries, not guaranteed deliverable energy.
20,265 kWhModeled year-one generation against 14,940 kWh of estimated annual use.

Equipment and design

Exact equipment listed in the proposal
ComponentModel and quantityRatings and listed terms
Solar panels32 × JA Solar JAM54D41-440440 W each; 14.08 kW DC total; 108 half-cut N-type cells; 1,762 × 1,134 mm. The proposal lists a 25-year manufacturer product warranty and a 30-year performance warranty.
Hybrid inverter1 × EG4 FlexBOSS2116 kW AC with PV, 12 kW battery-only, 21 kW PV input, three MPPTs. The proposal lists UL 1741 and UL 9540, and a 10-year manufacturer warranty.
Battery storage3 × EG4 PowerPro WallMount 14.3 kWh42.9 kWh rated total; 51.2 V LiFePO₄, integrated self-heating and IP65 enclosure. The proposal lists a 10-year manufacturer warranty.

The draft array modeled 32 panels at 159° azimuth and 20° slope. Final count, placement, orientation, and the indoor inverter and battery location would be confirmed at site survey and design. Backup depends on which circuits are connected and what they draw. Whole-home backup and a specific outage runtime were not promised.

What the cash quote included

Included in the proposal

  • Specified panels, inverter and three batteries, supplied and installed.
  • Mounting, rails, clamps, flashings, electrical parts and balance of system.
  • Installation labor, electrical integration, commissioning and testing.
  • Coordination of permits, inspections and utility interconnection.

Separate or excluded

  • Jurisdiction permit and inspection fees, unless included in writing, and an optional retailer smart meter.
  • Structural assessment or work, roof repairs or replacement, trenching and electrical service upgrades unless listed.
  • Concealed or added work requires a written change order.

The proposal shows no deposit and no incentives applied. It does not give installments or financing terms. It was non-binding; a separate signed agreement would be needed before work or payments. Interconnection, utility approval and inspection timing were not guaranteed.

How battery count changed the quoted price

Cash options from this specific proposal
BatteriesRated storageChange vs. baseSystem quote
228.6 kWh−$5,800$66,470
3 (as quoted)42.9 kWhBase quote$72,270
457.2 kWh+$5,800$78,070
571.5 kWh+$11,600$83,870

The quote priced each added or removed battery at $5,800. The production and bill forecast shown here applies to the three-battery option only.

What the first year was modeled to produce

The proposal modeled generation equal to about 136% of estimated annual consumption. That is a ratio of two estimates, not the share of the bill saved. It still modeled 1,611 kWh of grid imports and 6,284 kWh of exports. In January alone, it modeled 1,046 kWh of solar against 1,475 kWh of use, with 547 kWh of imports.

Modeled solar generation and estimated use by month
Estimated useModeled solarkWh

Exact values are also listed in the table below. Each pair uses the same scale.

Modeled first-year energy, kWh
MonthModeled solarEstimated useGrid importsGrid exports
Jan1,0461,47554764
Feb1,3561,318244228
Mar1,7481,09522615
Apr1,9749721954
May2,01896401,008
Jun2,1981,2652882
Jul2,1361,54440566
Aug2,0971,54542522
Sep1,7101,389119377
Oct1,7291,08028635
Nov1,210997138285
Dec1,0441,297428148
Total20,26614,9411,6116,284

Displayed months add up to 20,266 kWh of modeled solar and 14,941 kWh of estimated use. The annual headline figures are 20,265 and 14,940 kWh. The source says this 1 kWh difference in each total comes from rounding.

What the first-year bill model showed

The modeled bill fell from $1,862 to $367, a $1,495 reduction (about 80% under the proposal assumptions). Seven months were modeled at $18, not a zero bill. These are projected charges for the modeled home, not measured utility bills.

Modeled monthly bill before and after solar
Estimated bill beforeModeled bill afterDollars

Exact values are also listed in the table below. Each pair uses the same scale.

Modeled first-year bills and export credits, dollars
MonthExport creditBill beforeBill afterBill savings
Jan$1$179$78$101
Feb$4$162$42$120
Mar$11$138$18$120
Apr$17$123$18$105
May$18$122$18$104
Jun$16$161$18$143
Jul$10$192$18$174
Aug$9$192$18$174
Sep$7$174$27$147
Oct$11$134$18$116
Nov$5$125$30$95
Dec$3$160$64$96
Total$112$1,862$367$1,495

What the model assumed

  • Estimated use of 14,940 kWh a year; no account-specific tariff was given. The proposal modeled the Nashville Electric Service RS DPP residential rate.
  • Printed model assumptions: $0.11/kWh usage charge, $0.02/kWh export credit and $20.34 monthly fixed charge. These are not a statement of current rates, eligibility or utility commitments.
  • System Advisor Model 2020.02.29.r2; 14.7% total system losses, 3.1% inverter losses, 0% optimizer and shading losses, and 0% performance adjustment as reported. Do not add the loss categories. A separate annual degradation rate was not stated.
  • Financial assumptions: 4% annual energy cost escalation and a 6.75% discount rate. Unwarranted equipment replacement costs were not included.

The source does not specify the unrounded export rate or fully reconcile the printed tariff to its month-by-month output. Applying exactly $0.02 to 6,284 kWh does not reproduce the $112 modeled credit. The $18 modeled months do not establish that the printed $20.34 fixed charge was waived. Figures above are reported as modeled, not independently recomputed bills.

What the quote says about the longer term

Cumulative estimated bill savings
Illustrative bill savings curve from the proposal The curve rises to the source’s labeled estimate of forty-three thousand nine hundred ninety dollars at year twenty. Intermediate dollar values were not labeled. 05101520 years $43,990

The line follows the original proposal’s illustrative curve. The source labels only the $43,990 endpoint at year 20; intermediate dollar values were not supplied.

The proposal puts $43,990 of estimated lifetime bill savings beside the $72,270 quoted cash price, a $28,280 difference under its assumptions. That is not a payback promise, an investment return, or a full accounting of ownership cost.

Warranty, access and customer responsibilities as described in the proposal

The proposal describes a two-year workmanship warranty for specified installed work, separate from manufacturers’ stated equipment warranties. It describes correction of covered workmanship defects, not output, wear, storm or surge damage, or consequential damages. These are terms listed in this proposal, not current promises or an executed contract.

The proposal assigns roof structural adequacy, access, clearing equipment and belongings from work areas, property insurance and periodic maintenance to the homeowner. It describes reasonable property protection and written change orders for additional work. The utility controls interconnection approval and applicable rates, and the jurisdiction controls inspections. The separate signed agreement would govern actual scope and warranty.

Source: The Metal Roofers’ Nashville residential proposal, equipment and scope, modeled energy and bill tables, and quotation. No customer identifiers, site images, private files or live pricing are shown.