The Solar Roofers · Real proposal breakdown
Ashland City rooftop solar and battery proposal
A 67.76 kW design for a home with substantial estimated electrical use. See what it included, how the battery bank was sized in the proposal, and how the model behaved month by month.
01 · Scope and price
What was in the $323,400 quote?
Design a grid-connected rooftop solar system with battery backup for the main house. The proposal explains powering available loads with solar first, then storing excess in batteries and exporting surplus; no whole-home backup is promised. This was a proposed system. We have not verified installation, utility permission to operate, or actual production.
| Part | Quantity and model | Proposal specifications | Historical terms shown |
|---|---|---|---|
| Solar array | 154 × JA Solar JAM54D41-440 | 440 W per module; 67.760 kW DC total. The equipment page lists 108 half-cut N-type cells and 1,762 × 1,134 mm. | 25-year product and 30-year performance terms are listed for panels. |
| Hybrid inverters | 4 × EG4 FlexBOSS21 | Per unit: 16 kW AC with PV or 12 kW AC from batteries, 21 kW PV input and three trackers as listed in the quote. These ratings are not a promise for the combined backup circuits. | 10-year manufacturer term listed. |
| Battery storage | 12 × EG4 WallMount All Weather 280 Ah | 171.6 kWh listed total (14.3 kWh each); LiFePO4, 51.2 V and IP65 as listed. Listed storage is not energy delivered to the loads or guaranteed runtime. | 10-year manufacturer term listed. |
How the layout was proposed
| Roof plane | Panel count | Direction | Roof slope |
|---|---|---|---|
| Roof plane 1 | 100 | 154° azimuth | 29° |
| Roof plane 2 | 54 | 333° azimuth | 20° |
Panel count and roof layout are subject to survey and engineering; battery and inverter locations and backup circuit set are not final. The quote lists 2 years on installed workmanship, separate from equipment coverage. Current terms and manufacturer eligibility need their own written confirmation.
Included
- Supply and install panels, inverters and storage
- Mounting rails, clamps, flashings, electrical parts and other balance-of-system materials
- Installation labor and electrical integration
- Commissioning and testing before handover
- Coordinate permits, inspections and utility interconnection, subject to jurisdiction and utility approval
Separate or excluded
Permit and inspection fees are separately billed where applicable unless expressly included in writing. The proposal says no deposit and does not include a staged payment schedule. Its stated quote validity date was December 23, 2026; this is not an offer for another property.
- Optional retailer smart meter
- Roof repair or replacement
- Structural work
- Trenching
- Electrical service upgrades
- Uncovered equipment replacement costs are not included in the financial model
02 · Utility and production model
Projected generation is not the same as using less grid power
The proposal headlines 88,878 kWh of estimated first-year generation against 59,900 kWh of assumed annual use, or about 148%. The baseline was estimated, not a verified utility bill. In January the model still imports 2,012 kWh from the grid.
How to read the dollar estimates: the proposal assumed a specific Nashville Electric Service scenario rather than a verified account rate. The modeled export credits and some after-solar bills do not reconcile to the displayed rate and fixed charge alone. Figures below show the original modeled output, not a verified rate, savings forecast for your home, or a guaranteed bill.
Assumptions printed in the proposal
| Input | Value as printed |
|---|---|
| Production model | System Advisor Model 2020.02.29.r2, as printed |
| System and inverter losses | 15.2% system losses; 3.1% inverter losses |
| Shading and other adjustments | 0% shading loss, 0% optimizer loss and 0% performance adjustment in the model; not a measured site condition |
| Electricity rate scenario | Nashville Electric Service RS DPP residential; no account rate was supplied |
| Rates assumed | $0.11/kWh for use; $0.02/kWh displayed export credit; $20.34 displayed monthly fixed charge |
| Financial assumptions | 4% assumed annual electricity price increase; 6.75% discount rate; no unmodeled equipment replacement costs |
Modeled solar generationEstimated use
Before solar and storageAfter solar and storage
Full monthly figures
| Month | Solar (kWh) | Use (kWh) | Imports (kWh) | Exports (kWh) | Export credit | Bill before | Bill after | Bill difference |
|---|---|---|---|---|---|---|---|---|
| Jan | 4,343 | 5,913 | 2,012 | 212 | $4 | $656 | $233 | $423 |
| Feb | 5,723 | 5,283 | 768 | 975 | $18 | $588 | $85 | $503 |
| Mar | 7,567 | 4,392 | 37 | 2,968 | $53 | $492 | $18 | $474 |
| Apr | 8,804 | 3,896 | 0 | 4,716 | $85 | $431 | $18 | $413 |
| May | 9,237 | 3,864 | 0 | 5,195 | $94 | $428 | $18 | $410 |
| Jun | 10,155 | 5,070 | 0 | 4,879 | $88 | $583 | $18 | $565 |
| Jul | 9,834 | 6,191 | 52 | 3,430 | $62 | $707 | $18 | $689 |
| Aug | 9,430 | 6,194 | 82 | 3,033 | $55 | $707 | $18 | $689 |
| Sep | 7,470 | 5,570 | 390 | 2,038 | $37 | $637 | $27 | $610 |
| Oct | 7,229 | 4,330 | 71 | 2,790 | $50 | $476 | $18 | $458 |
| Nov | 4,949 | 3,998 | 476 | 1,170 | $21 | $442 | $49 | $393 |
| Dec | 4,138 | 5,201 | 1,656 | 481 | $9 | $579 | $190 | $389 |
| Printed total | 88,879 | 59,902 | 5,544 | 31,887 | $576 | $6,726 | $710 | $6,016 |
Reproduce the proposal's printed totals and note row-level rounding. The 88,879 kWh and 59,902 kWh monthly displayed totals differ by 1 and 2 kWh from the headline annual estimates. The separately stated $20.34 fixed charge is above the $18 after-solar figure shown for several months. The printed $576 export credit likewise does not equal exported kWh multiplied by the displayed two-cent rate; unshown assumptions may affect those results.
The proposal compared $323,400 upfront with $177,463 in illustrative 20-year bill savings. In that model, the savings alone fall $145,937 short of the quoted cost, before other costs. Backup power is a separate design goal, not a claim of financial payback.
How the proposed system would operate
In daylight, solar can serve available loads. Excess can charge the batteries and, when permitted, export. When generation is low, loads can use configured storage or draw from the grid. Which circuits run during an outage depends on the final equipment and electrical design.
Source: an anonymized The Metal Roofers residential proposal, including its equipment schedule and generation and bill modeling pages. No names, addresses, property images or raw customer documents are reproduced.
Companion house: 23.22 kW solar with 85.8 kWh of storage
The same project reference also contains a separate $129,720 companion design labeled for the second house, not another copy of the main-house design. The two proposals used the same 59,900 kWh annual usage input. Separate meter histories, concurrent work, payment, utility approval, and installation were not verified, so the figures should not be added into a single completed project.
| Scope | Main-house design | Companion house design |
|---|---|---|
| Quoted price | $323,400 | $129,720 |
| DC solar | 67.760 kW from 154 JA Solar 440 W panels | 23.220 kW from 43 Jinko JKM540M-72HL4-V modules at 540 W each |
| Hybrid inverters | Four EG4 FlexBOSS21 units, aggregate quoted 64 kW with PV | One EG4 18kPV-12LV and one EG4 FlexBOSS21, aggregate quoted 28 kW with PV |
| Nominal storage as quoted | 12 EG4 WallMount All Weather units, 171.6 kWh | Six EG4 WallMount All Weather 280 Ah, 14.3 kWh each, 85.8 kWh |
| Predicted annual PV | 88,878 kWh | 30,113 kWh |
| Production-to-use ratio | 148% | 50% |
| Projected annual utility bill | $710 after, vs. $6,726 modeled before | $3,593 after, vs. $6,726 modeled before |
In the companion design, 18 and 25 modules were drawn on two arrays at 95° azimuth and 20° slope. The quote covered the panels, both inverters, storage, mounting and balance of system, installation, integration and commissioning. Permit/inspection fees were separate unless included in writing; an optional utility smart meter was not included. The source lists a cash quote through December 23, 2026 with no deposit stated. Quoted storage does not verify usable capacity for a given circuit or outage duration.
| Month | Forecast PV (kWh) | Estimated use (kWh) | Modeled imports (kWh) | Modeled exports (kWh) | Export credit | Model bill before | Model bill after | Difference as printed |
|---|---|---|---|---|---|---|---|---|
| Jan | 1,379 | 5,913 | 4,548 | 0 | $0 | $656 | $509 | $147 |
| Feb | 1,861 | 5,283 | 3,459 | 0 | $0 | $588 | $392 | $196 |
| Mar | 2,544 | 4,392 | 1,941 | 7 | $0 | $492 | $229 | $263 |
| Apr | 3,033 | 3,896 | 1,118 | 138 | $2 | $431 | $136 | $295 |
| May | 3,241 | 3,864 | 903 | 150 | $3 | $428 | $113 | $315 |
| Jun | 3,635 | 5,070 | 1,593 | 48 | $1 | $583 | $196 | $387 |
| Jul | 3,483 | 6,191 | 2,797 | 0 | $0 | $707 | $331 | $376 |
| Aug | 3,277 | 6,194 | 2,999 | 0 | $0 | $707 | $353 | $354 |
| Sep | 2,563 | 5,570 | 3,069 | 0 | $0 | $637 | $360 | $277 |
| Oct | 2,339 | 4,330 | 2,072 | 0 | $0 | $476 | $239 | $237 |
| Nov | 1,543 | 3,998 | 2,498 | 0 | $0 | $442 | $284 | $158 |
| Dec | 1,217 | 5,201 | 4,004 | 0 | $0 | $579 | $451 | $128 |
| Printed annual | 30,115 | 59,902 | 31,001 | 343 | $6 | $6,726 | $3,593 | $3,133 |
The printed monthly table sums to 30,115 kWh solar and 59,902 kWh use; the annual cover instead shows 30,113 and 59,900 kWh. The table models 31,001 kWh imported, 343 kWh exported and $6 reported export credit. The historical tariff assumptions name $0.11/kWh retail, $0.02/kWh export, and a $20.34 fixed monthly charge, with 4% price escalation and a 6.75% financial discount. The stated export rate may not reproduce displayed whole-dollar credit values. A current account tariff or export agreement was not verified.
The historical equipment model used System Advisor Model 2020.02.29.r2 with 16.3% system losses, 3.1% inverter losses and no optimizer, shading or separate performance adjustment. The model reports $3,133 of first-year bill difference and $88,167 over 20 years, or $41,553 less than the proposed cash price before separate fees. Those are conditional model outputs, not actual savings, guaranteed returns or a contract decision.
The manufacturer terms listed in the proposal were 12-year Jinko product and 25-year performance coverage and 10 years for the quoted inverter and battery models. These are historical proposal terms, not a new warranty offer. Source basis: companion eight-page residential estimate, design and pricing on pages 1–3 and 6, historical model on pages 4–6. No identifiable aerial, private document or photograph of a completed installation is shown.