Ardmore, Tennessee · Historical commercial rooftop solar proposal
A 69.6 kW rooftop solar model for an Ardmore business
A May 2024 design for an Ardmore business modeled a 69.6 kW rooftop array against 125,360 kWh of reported annual electricity use. The gross estimate was $199,500. The tables below reproduce the baseline and projected billing figures separately so a projection is never mistaken for a utility bill after installation.
- 145 × 480 W modules in the proposal
- 69.6 kW DC
- Modeled first-year solar generation
- 92,729 kWh
- Historical gross project estimate before incentives
- $199,500
How was the commercial array sized?
The sizing compared the estimated rooftop generation with a year of utility use. The proposal listed 92,729 kWh of first-year solar energy, about 74% of the 125,360 kWh reported use. This ratio does not mean 74% of the bill was removed or that solar served 74% of every hour.
| Item | Historical source figure |
|---|---|
| PV array | 145 Qcells Q.PEAK DUO XL-G10.d modules, each 480 W, for 69,600 W DC. |
| Conversion equipment | Five SolarEdge SE11400H-US (208 V) inverters were listed. No battery bank was specified. |
| AC model field | The source separately lists 60,626 W AC. The report did not reconcile this field with its inverter schedule, so it is not a verified AC limit or export capacity. |
| Utility assumption | The model uses the listed PES GSA2 rate schedule before and with solar. These are historical inputs, not a verified current tariff. |
| Baseline and projection | $17,028 annual utility bill baseline; $8,146 modeled with solar; $8,881 annual savings reported by the model. Displayed charges and differences can vary by $1 because the source rounds separately. |
| Gross project estimate | $199,500, before incentives. No quote acceptance, grant, tax result, financing, job invoice, power-on, or measured result verified. |
No installer completion, final construction drawings, equipment delivery or metered generation is claimed. No site-identifying aerial or proposal screenshot is reproduced.
The baseline: 12 billing periods without solar
These are the billing inputs reproduced in the proposal, not independently audited account records. The date rows preserve the source's January-to-December reporting order and use both 2023 and 2024 billing periods.
| Billing period | Use (kWh) | Max demand (kW) | Other charges | Energy | Demand charges | Total bill |
|---|---|---|---|---|---|---|
| Jan 7–Feb 7, 2024 | 11,200 | 34 | $152 | $1,326 | $0 | $1,478 |
| Feb 7–Mar 7, 2024 | 12,560 | 41 | $152 | $1,487 | $0 | $1,639 |
| Mar 7–Apr 7, 2024 | 5,120 | 16 | $152 | $606 | $0 | $758 |
| Apr 7–May 7, 2024 | 6,480 | 22 | $152 | $767 | $0 | $919 |
| May 7–Jun 7, 2024 | 8,080 | 31 | $152 | $957 | $0 | $1,109 |
| Jun 7–Jul 7, 2023 | 10,080 | 42 | $152 | $1,193 | $0 | $1,346 |
| Jul 7–Aug 7, 2023 | 13,280 | 54 | $152 | $1,572 | $66 | $1,791 |
| Aug 7–Sep 7, 2023 | 15,440 | 60 | $152 | $1,806 | $165 | $2,123 |
| Sep 7–Oct 7, 2023 | 14,960 | 59 | $152 | $1,771 | $149 | $2,072 |
| Oct 7–Nov 7, 2023 | 11,120 | 38 | $152 | $1,317 | $0 | $1,469 |
| Nov 7–Dec 7, 2023 | 8,240 | 27 | $152 | $976 | $0 | $1,128 |
| Dec 7, 2023–Jan 7, 2024 | 8,800 | 28 | $152 | $1,042 | $0 | $1,194 |
| Annual total as printed | 125,360 | Not given | $1,827 | $14,820 | $380 | $17,028 |
The projection: the same periods with modeled solar
The post-solar figures are forecasts. Negative estimated net use appears in four periods, but the projection still shows bill charges in every period. A monthly net surplus does not imply grid independence or eliminate fixed and demand charges.
| Billing period | Net use (kWh) | Max demand (kW) | Other charges | Energy | Demand charges | Total bill |
|---|---|---|---|---|---|---|
| Jan 7–Feb 7, 2024 | 5,926 | 34 | $152 | $781 | $0 | $934 |
| Feb 7–Mar 7, 2024 | 7,130 | 39 | $152 | $960 | $0 | $1,112 |
| Mar 7–Apr 7, 2024 | −2,851 | 15 | $152 | $34 | $0 | $186 |
| Apr 7–May 7, 2024 | −2,382 | 16 | $152 | $72 | $0 | $225 |
| May 7–Jun 7, 2024 | −2,610 | 22 | $152 | $94 | $0 | $246 |
| Jun 7–Jul 7, 2023 | −334 | 34 | $152 | $250 | $0 | $402 |
| Jul 7–Aug 7, 2023 | 2,434 | 39 | $152 | $491 | $0 | $643 |
| Aug 7–Sep 7, 2023 | 5,989 | 53 | $152 | $836 | $50 | $1,038 |
| Sep 7–Oct 7, 2023 | 6,660 | 40 | $152 | $902 | $0 | $1,055 |
| Oct 7–Nov 7, 2023 | 4,375 | 37 | $152 | $665 | $0 | $817 |
| Nov 7–Dec 7, 2023 | 3,455 | 27 | $152 | $544 | $0 | $696 |
| Dec 7, 2023–Jan 7, 2024 | 4,840 | 28 | $152 | $641 | $0 | $793 |
| Annual total as printed | 32,632 | Not given | $1,827 | $6,270 | $50 | $8,146 |
The source also prints 32,631 kWh as the remainder in its annual comparison and 32,632 kWh in its detailed table. Both are reproduced where relevant to the original model rather than silently changing them.
The level of peak demand is a separate issue from annual energy. The model's post-solar demand charge is still $50 over the reported year. Buyers comparing commercial proposals should ask how peaks, seasonal schedules, fixed charges and excess production are modeled.
What did the older long-term model project?
The source also illustrated 25 years of generation and avoided utility-bill costs at an assumed 4% annual utility escalation. That assumption is not a rate forecast. These are not actual results, a current financing offer, an analysis of current tax eligibility or proof of incentive payments.
| Model year | Modeled PV output (kWh) | Modeled bill savings |
|---|---|---|
| 1 | 92,728 | $8,881 |
| 2 | 91,987 | $9,163 |
| 3 | 91,245 | $9,452 |
| 4 | 90,503 | $9,750 |
| 5 | 89,761 | $10,057 |
| 6 | 89,019 | $10,373 |
| 7 | 88,277 | $10,698 |
| 8 | 87,536 | $11,033 |
| 9 | 86,794 | $11,377 |
| 10 | 86,052 | $11,731 |
| 11 | 85,310 | $12,095 |
| 12 | 84,568 | $12,469 |
| 13 | 83,826 | $12,854 |
| 14 | 83,085 | $13,250 |
| 15 | 82,343 | $13,657 |
| 16 | 81,601 | $14,075 |
| 17 | 80,859 | $14,505 |
| 18 | 80,117 | $14,947 |
| 19 | 79,376 | $15,401 |
| 20 | 78,634 | $15,867 |
| 21 | 77,892 | $16,346 |
| 22 | 77,150 | $16,838 |
| 23 | 76,408 | $17,343 |
| 24 | 75,666 | $17,862 |
| 25 | 74,925 | $18,394 |
| Printed 25-year total | 2,095,662 | $328,417 |
The detailed cash-flow table uses 92,728 kWh for year one, while the design summary uses 92,729. The financial branches in the source depend on historical incentive and financing assumptions; no modeled eligibility, net incentive price, ROI or payback is asserted here.
Compare your business's utility profile, not just system size
For your own commercial project, share a year of bills, service voltage, any measured demand and the hours the building runs. Ask the designer for a separate baseline, modeled charges and generation estimate.
Ask about commercial rooftop solarSource: Anonymized May 2024 commercial solar design retained in the project archive, pp. 2–4 and 7–8. Quoted and modeled only; not evidence of installation, verified incentives or measured savings.