Ardmore, Tennessee · Historical commercial rooftop solar proposal

A 69.6 kW rooftop solar model for an Ardmore business

A May 2024 design for an Ardmore business modeled a 69.6 kW rooftop array against 125,360 kWh of reported annual electricity use. The gross estimate was $199,500. The tables below reproduce the baseline and projected billing figures separately so a projection is never mistaken for a utility bill after installation.

145 × 480 W modules in the proposal
69.6 kW DC
Modeled first-year solar generation
92,729 kWh
Historical gross project estimate before incentives
$199,500

How was the commercial array sized?

The sizing compared the estimated rooftop generation with a year of utility use. The proposal listed 92,729 kWh of first-year solar energy, about 74% of the 125,360 kWh reported use. This ratio does not mean 74% of the bill was removed or that solar served 74% of every hour.

Historical design comparison
125,360 kWh: reported annual use
92,729 kWh: modeled annual solar generation
Equipment, rates and annual figures shown in the model
ItemHistorical source figure
PV array145 Qcells Q.PEAK DUO XL-G10.d modules, each 480 W, for 69,600 W DC.
Conversion equipmentFive SolarEdge SE11400H-US (208 V) inverters were listed. No battery bank was specified.
AC model fieldThe source separately lists 60,626 W AC. The report did not reconcile this field with its inverter schedule, so it is not a verified AC limit or export capacity.
Utility assumptionThe model uses the listed PES GSA2 rate schedule before and with solar. These are historical inputs, not a verified current tariff.
Baseline and projection$17,028 annual utility bill baseline; $8,146 modeled with solar; $8,881 annual savings reported by the model. Displayed charges and differences can vary by $1 because the source rounds separately.
Gross project estimate$199,500, before incentives. No quote acceptance, grant, tax result, financing, job invoice, power-on, or measured result verified.

No installer completion, final construction drawings, equipment delivery or metered generation is claimed. No site-identifying aerial or proposal screenshot is reproduced.

The baseline: 12 billing periods without solar

These are the billing inputs reproduced in the proposal, not independently audited account records. The date rows preserve the source's January-to-December reporting order and use both 2023 and 2024 billing periods.

Reported utility baseline
Billing periodUse (kWh)Max demand (kW)Other chargesEnergyDemand chargesTotal bill
Jan 7–Feb 7, 202411,20034$152$1,326$0$1,478
Feb 7–Mar 7, 202412,56041$152$1,487$0$1,639
Mar 7–Apr 7, 20245,12016$152$606$0$758
Apr 7–May 7, 20246,48022$152$767$0$919
May 7–Jun 7, 20248,08031$152$957$0$1,109
Jun 7–Jul 7, 202310,08042$152$1,193$0$1,346
Jul 7–Aug 7, 202313,28054$152$1,572$66$1,791
Aug 7–Sep 7, 202315,44060$152$1,806$165$2,123
Sep 7–Oct 7, 202314,96059$152$1,771$149$2,072
Oct 7–Nov 7, 202311,12038$152$1,317$0$1,469
Nov 7–Dec 7, 20238,24027$152$976$0$1,128
Dec 7, 2023–Jan 7, 20248,80028$152$1,042$0$1,194
Annual total as printed125,360Not given$1,827$14,820$380$17,028

The projection: the same periods with modeled solar

The post-solar figures are forecasts. Negative estimated net use appears in four periods, but the projection still shows bill charges in every period. A monthly net surplus does not imply grid independence or eliminate fixed and demand charges.

Modeled utility bills with the proposed solar design
Billing periodNet use (kWh)Max demand (kW)Other chargesEnergyDemand chargesTotal bill
Jan 7–Feb 7, 20245,92634$152$781$0$934
Feb 7–Mar 7, 20247,13039$152$960$0$1,112
Mar 7–Apr 7, 2024−2,85115$152$34$0$186
Apr 7–May 7, 2024−2,38216$152$72$0$225
May 7–Jun 7, 2024−2,61022$152$94$0$246
Jun 7–Jul 7, 2023−33434$152$250$0$402
Jul 7–Aug 7, 20232,43439$152$491$0$643
Aug 7–Sep 7, 20235,98953$152$836$50$1,038
Sep 7–Oct 7, 20236,66040$152$902$0$1,055
Oct 7–Nov 7, 20234,37537$152$665$0$817
Nov 7–Dec 7, 20233,45527$152$544$0$696
Dec 7, 2023–Jan 7, 20244,84028$152$641$0$793
Annual total as printed32,632Not given$1,827$6,270$50$8,146

The source also prints 32,631 kWh as the remainder in its annual comparison and 32,632 kWh in its detailed table. Both are reproduced where relevant to the original model rather than silently changing them.

The level of peak demand is a separate issue from annual energy. The model's post-solar demand charge is still $50 over the reported year. Buyers comparing commercial proposals should ask how peaks, seasonal schedules, fixed charges and excess production are modeled.

What did the older long-term model project?

The source also illustrated 25 years of generation and avoided utility-bill costs at an assumed 4% annual utility escalation. That assumption is not a rate forecast. These are not actual results, a current financing offer, an analysis of current tax eligibility or proof of incentive payments.

Generation and modeled bill savings from the original annual cash-flow series
Model yearModeled PV output (kWh)Modeled bill savings
192,728$8,881
291,987$9,163
391,245$9,452
490,503$9,750
589,761$10,057
689,019$10,373
788,277$10,698
887,536$11,033
986,794$11,377
1086,052$11,731
1185,310$12,095
1284,568$12,469
1383,826$12,854
1483,085$13,250
1582,343$13,657
1681,601$14,075
1780,859$14,505
1880,117$14,947
1979,376$15,401
2078,634$15,867
2177,892$16,346
2277,150$16,838
2376,408$17,343
2475,666$17,862
2574,925$18,394
Printed 25-year total2,095,662$328,417

The detailed cash-flow table uses 92,728 kWh for year one, while the design summary uses 92,729. The financial branches in the source depend on historical incentive and financing assumptions; no modeled eligibility, net incentive price, ROI or payback is asserted here.

Compare your business's utility profile, not just system size

For your own commercial project, share a year of bills, service voltage, any measured demand and the hours the building runs. Ask the designer for a separate baseline, modeled charges and generation estimate.

Ask about commercial rooftop solar

Source: Anonymized May 2024 commercial solar design retained in the project archive, pp. 2–4 and 7–8. Quoted and modeled only; not evidence of installation, verified incentives or measured savings.