The Solar Roofers · Historical design example

51.84 kW solar and battery backup proposal

A proposed residential system with 96 panels, two roof orientations and six batteries. The documented cash quote was $170,000 for the listed equipment and work. It was valid through October 23, 2026.

Quoted cash price
$170,000
Proposed DC capacity
51.840 kW
Quoted battery capacity
86.04 kWh

Modeled design, not proof of installation, payment, savings or current pricing. Customer and property identifiers removed.

What the $170,000 quote included

Quoted equipment and installation scope
ItemDesign and scopePricing treatment
Solar array96 Jinko JKM540M-72HL4-V modules at 540 W each. Two 48-panel arrays; proposed azimuths 180° and 0°, both at 25° slope.Supplied and installed
Hybrid inverters3 EG4 FlexBOSS21 units; the proposal lists 16 kW AC each with PV, 12 kW each battery-only, and 21 kW PV input with three MPPTs each.Included. 48 kW AC with PV is a proposed aggregate rating, not a backup load guarantee.
Battery storage6 EG4 WallMount Indoor 280 Ah batteries, LiFePO4, 51.2 V. Quoted total 86.04 kWh; actual runtime depends on electrical design and loads.Included
Mounting and balance of systemRails, clamps, flashings, electrical parts, labor, commissioning and testing.Included
IncentivesNone applied or promised.$0 applied
Quoted cash totalGross for listed scope before separate fees$170,000

What was separate

Permit and inspection fees are billed separately unless expressly included. A retailer smart meter, structural engineering assessment, roof repair or replacement, structural work, trenching and service upgrades are outside the quoted scope unless added in writing. The proposal coordinates utility interconnection; it does not confirm utility approval, rate eligibility or permission to operate.

First-year production, usage and bill model

The proposal modeled 61,595 kWh of first-year solar generation against 30,000 kWh of estimated annual household use, or 205.32%. That ratio is not a savings percentage, a guarantee of off-grid operation, or measured consumption. The model still has 1,593 kWh imported and 31,814 kWh exported over the year.

The model uses System Advisor Model 2020.02.29.r2; total system losses 16.9%, inverter losses 3.1%, optimizer and shade losses 0%, no additional performance adjustment, and the proposed orientations above. The assumed NES RS DPP tariff uses $0.11/kWh retail, $0.02/kWh export and a $20.34 monthly fixed charge. The actual account rate was not verified. Financial inputs were 4% annual energy-price escalation and 6.75% discount rate, excluding out-of-warranty replacement costs.

Modeled monthly solar generation vs. estimated household use (kWh)
Forecast generationEstimated use
All twelve months are forecast or estimated, not recorded utility use. Exact values and modeled grid flows are in the table below.02,7005,4008,100Jan · Forecast generation: 2,778Feb · Forecast generation: 3,737Mar · Forecast generation: 5,146Apr · Forecast generation: 6,276May · Forecast generation: 6,815Jun · Forecast generation: 7,574Jul · Forecast generation: 7,286Aug · Forecast generation: 6,758Sep · Forecast generation: 5,102Oct · Forecast generation: 4,621Nov · Forecast generation: 3,044Dec · Forecast generation: 2,457Jan · Estimated use: 2,961Feb · Estimated use: 2,646Mar · Estimated use: 2,200Apr · Estimated use: 1,951May · Estimated use: 1,935Jun · Estimated use: 2,539Jul · Estimated use: 3,101Aug · Estimated use: 3,102Sep · Estimated use: 2,790Oct · Estimated use: 2,168Nov · Estimated use: 2,002Dec · Estimated use: 2,605JanFebMarAprMayJunJulAugSepOctNovDec
Source model: first-year bills before and after solar plus storage (USD)
Model bill beforeModel bill after
Modeled values shown for transparency, not a savings promise. Source model does not reconcile the export credit or fixed charge as explained above.$0$125$250$375Jan · Model bill before: $339Feb · Model bill before: $305Mar · Model bill before: $257Apr · Model bill before: $226May · Model bill before: $225Jun · Model bill before: $302Jul · Model bill before: $364Aug · Model bill before: $364Sep · Model bill before: $329Oct · Model bill before: $249Nov · Model bill before: $231Dec · Model bill before: $300Jan · Model bill after: $80Feb · Model bill after: $18Mar · Model bill after: $18Apr · Model bill after: $18May · Model bill after: $18Jun · Model bill after: $18Jul · Model bill after: $18Aug · Model bill after: $18Sep · Model bill after: $18Oct · Model bill after: $18Nov · Model bill after: $18Dec · Model bill after: $84JanFebMarAprMayJunJulAugSepOctNovDec
All 12 months exactly as displayed in the source table (modeled). Financial columns are under review.
MonthForecast PV kWhEstimated use kWhModeled imports kWhModeled exports kWhReported export creditModel bill beforeModel bill afterReported difference
Jan2,7782,961602270$5$339$80$259
Feb3,7372,6461011,053$19$305$18$287
Mar5,1462,20002,825$51$257$18$239
Apr6,2761,95104,233$76$226$18$208
May6,8151,93504,794$86$225$18$207
Jun7,5742,53904,937$89$302$18$284
Jul7,2863,10104,059$73$364$18$346
Aug6,7583,10203,517$63$364$18$346
Sep5,1022,7901002,282$41$329$18$311
Oct4,6212,16802,345$42$249$18$231
Nov3,0442,0021241,047$19$231$18$213
Dec2,4572,605666452$8$300$84$216
Printed total61,59530,0001,59331,814$572$3,491$344$3,147

The displayed monthly generation rows total 61,594 kWh, one less than the printed annual headline. The original annual total remains labeled as printed. January imports are modeled at 602 kWh and December imports at 666 kWh despite the annual production surplus.

Original terms, other figures and evidence limits

The source charts cumulative estimated bill savings at years 1, 5, 10, 15 and 20, but prints no exact intermediate values. The labeled year-20 endpoint is $93,788. The model’s quoted cost less lifetime savings is $76,212. These financial outputs are on hold; no missing chart points, return or payoff date have been invented.

Source model: cumulative estimated bill savings over 20 years
Shape redrawn directly from all 21 points of the original proposal graphic. Only the printed year-20 amount, $93,788, is labeled. Financial model under review, not actual savings.15101520Year 20: $93,788Year in source model

The shape follows the source PDF’s exact vector path. The proposal prints no exact interim dollar values. This model is under review and is not a guaranteed return.

The environmental graphic lists 22 tons of CO₂ per modeled year, 402,391 lifetime car miles equivalent, 4,166 trees equivalent and 464 long-haul flights equivalent. These are illustrative, methodology-dependent estimates, not measured or certified reductions.

The proposal described two years of installation workmanship coverage, Jinko warranties of 12 years product and 25 years performance, and 10-year manufacturer terms for the quoted EG4 inverters and batteries. These are historical proposal terms, not current warranties or verified eligibility.

Source basis: Archived 10-page residential proposal: design and equipment (pages 1–3), site context (4–5), annual and monthly model (6–7), quotation and cumulative chart (8), and terms (9–10). Site imagery, quote identifiers and private documents are omitted. No installed system, measured production, invoice or payment was verified.

The Solar Roofers · Site-specific designs

Get a quote based on your property

Equipment, usage and scope vary. Ask us to compare your utility use, roof layout, electrical requirements and backup goals before you decide.

Talk with our solar team See the solar design library

Cross-check against the original design export

We checked the formatted $170,000 proposal against the original design export for the same property. Both show the same 51.84 kW design, 61,595 kWh annual generation forecast and 30,000 kWh estimated annual use. The monthly solar, usage, import, export, export-credit and both bill figures also match.

Five monthly bill-difference displays differed by $1 between proposal versions
MonthOriginal design exportFormatted historical proposal
January$258$259
February$286$287
March$238$239
May$206$207
October$230$231

The source files do not reconcile those display differences. The monthly table above preserves the formatted proposal’s figures. Neither version documents payment, installation, measured consumption or realized savings.

What the site looked like before solar

These photos show existing conditions at the site visit for the proposed 51.84 kW system. They do not show an installed array or batteries.

Existing electrical service and conduit at the pre-installation site visit
Existing electrical service photographed during the site visit. This is the equipment already at the property, not the proposed solar or battery installation.
Partial shop roof still under construction with no solar modules visible
The shop roof was still under construction during the site visit. No solar modules are visible in this photo.