The Solar Roofers · Historical design example
51.84 kW solar and battery backup proposal
A proposed residential system with 96 panels, two roof orientations and six batteries. The documented cash quote was $170,000 for the listed equipment and work. It was valid through October 23, 2026.
- Quoted cash price
- $170,000
- Proposed DC capacity
- 51.840 kW
- Quoted battery capacity
- 86.04 kWh
Modeled design, not proof of installation, payment, savings or current pricing. Customer and property identifiers removed.
What the $170,000 quote included
| Item | Design and scope | Pricing treatment |
|---|---|---|
| Solar array | 96 Jinko JKM540M-72HL4-V modules at 540 W each. Two 48-panel arrays; proposed azimuths 180° and 0°, both at 25° slope. | Supplied and installed |
| Hybrid inverters | 3 EG4 FlexBOSS21 units; the proposal lists 16 kW AC each with PV, 12 kW each battery-only, and 21 kW PV input with three MPPTs each. | Included. 48 kW AC with PV is a proposed aggregate rating, not a backup load guarantee. |
| Battery storage | 6 EG4 WallMount Indoor 280 Ah batteries, LiFePO4, 51.2 V. Quoted total 86.04 kWh; actual runtime depends on electrical design and loads. | Included |
| Mounting and balance of system | Rails, clamps, flashings, electrical parts, labor, commissioning and testing. | Included |
| Incentives | None applied or promised. | $0 applied |
| Quoted cash total | Gross for listed scope before separate fees | $170,000 |
What was separate
Permit and inspection fees are billed separately unless expressly included. A retailer smart meter, structural engineering assessment, roof repair or replacement, structural work, trenching and service upgrades are outside the quoted scope unless added in writing. The proposal coordinates utility interconnection; it does not confirm utility approval, rate eligibility or permission to operate.
First-year production, usage and bill model
The proposal modeled 61,595 kWh of first-year solar generation against 30,000 kWh of estimated annual household use, or 205.32%. That ratio is not a savings percentage, a guarantee of off-grid operation, or measured consumption. The model still has 1,593 kWh imported and 31,814 kWh exported over the year.
The model uses System Advisor Model 2020.02.29.r2; total system losses 16.9%, inverter losses 3.1%, optimizer and shade losses 0%, no additional performance adjustment, and the proposed orientations above. The assumed NES RS DPP tariff uses $0.11/kWh retail, $0.02/kWh export and a $20.34 monthly fixed charge. The actual account rate was not verified. Financial inputs were 4% annual energy-price escalation and 6.75% discount rate, excluding out-of-warranty replacement costs.
| Month | Forecast PV kWh | Estimated use kWh | Modeled imports kWh | Modeled exports kWh | Reported export credit | Model bill before | Model bill after | Reported difference |
|---|---|---|---|---|---|---|---|---|
| Jan | 2,778 | 2,961 | 602 | 270 | $5 | $339 | $80 | $259 |
| Feb | 3,737 | 2,646 | 101 | 1,053 | $19 | $305 | $18 | $287 |
| Mar | 5,146 | 2,200 | 0 | 2,825 | $51 | $257 | $18 | $239 |
| Apr | 6,276 | 1,951 | 0 | 4,233 | $76 | $226 | $18 | $208 |
| May | 6,815 | 1,935 | 0 | 4,794 | $86 | $225 | $18 | $207 |
| Jun | 7,574 | 2,539 | 0 | 4,937 | $89 | $302 | $18 | $284 |
| Jul | 7,286 | 3,101 | 0 | 4,059 | $73 | $364 | $18 | $346 |
| Aug | 6,758 | 3,102 | 0 | 3,517 | $63 | $364 | $18 | $346 |
| Sep | 5,102 | 2,790 | 100 | 2,282 | $41 | $329 | $18 | $311 |
| Oct | 4,621 | 2,168 | 0 | 2,345 | $42 | $249 | $18 | $231 |
| Nov | 3,044 | 2,002 | 124 | 1,047 | $19 | $231 | $18 | $213 |
| Dec | 2,457 | 2,605 | 666 | 452 | $8 | $300 | $84 | $216 |
| Printed total | 61,595 | 30,000 | 1,593 | 31,814 | $572 | $3,491 | $344 | $3,147 |
The displayed monthly generation rows total 61,594 kWh, one less than the printed annual headline. The original annual total remains labeled as printed. January imports are modeled at 602 kWh and December imports at 666 kWh despite the annual production surplus.
Original terms, other figures and evidence limits
The source charts cumulative estimated bill savings at years 1, 5, 10, 15 and 20, but prints no exact intermediate values. The labeled year-20 endpoint is $93,788. The model’s quoted cost less lifetime savings is $76,212. These financial outputs are on hold; no missing chart points, return or payoff date have been invented.
The shape follows the source PDF’s exact vector path. The proposal prints no exact interim dollar values. This model is under review and is not a guaranteed return.
The environmental graphic lists 22 tons of CO₂ per modeled year, 402,391 lifetime car miles equivalent, 4,166 trees equivalent and 464 long-haul flights equivalent. These are illustrative, methodology-dependent estimates, not measured or certified reductions.
The proposal described two years of installation workmanship coverage, Jinko warranties of 12 years product and 25 years performance, and 10-year manufacturer terms for the quoted EG4 inverters and batteries. These are historical proposal terms, not current warranties or verified eligibility.
Source basis: Archived 10-page residential proposal: design and equipment (pages 1–3), site context (4–5), annual and monthly model (6–7), quotation and cumulative chart (8), and terms (9–10). Site imagery, quote identifiers and private documents are omitted. No installed system, measured production, invoice or payment was verified.
The Solar Roofers · Site-specific designs
Get a quote based on your property
Equipment, usage and scope vary. Ask us to compare your utility use, roof layout, electrical requirements and backup goals before you decide.
Talk with our solar team See the solar design libraryCross-check against the original design export
We checked the formatted $170,000 proposal against the original design export for the same property. Both show the same 51.84 kW design, 61,595 kWh annual generation forecast and 30,000 kWh estimated annual use. The monthly solar, usage, import, export, export-credit and both bill figures also match.
| Month | Original design export | Formatted historical proposal |
|---|---|---|
| January | $258 | $259 |
| February | $286 | $287 |
| March | $238 | $239 |
| May | $206 | $207 |
| October | $230 | $231 |
The source files do not reconcile those display differences. The monthly table above preserves the formatted proposal’s figures. Neither version documents payment, installation, measured consumption or realized savings.