Historical residential solar and storage proposal

A 25.5 kW solar proposal for a home with high electricity use

For this proposed system, 60 solar modules and four batteries were modeled against an estimated annual electricity use of roughly 64,000 kWh. The cash quote was $129,290 before any incentives. Even with a forecast of more than 33,000 kWh of solar, the model still shows utility charges every month.

60 × 425 W Jinko modules on two modeled orientations
25.5 kW DC
Four EG4 PowerPro WallMount batteries
57.2 kWh listed
Historical gross cash price, not an accepted or paid amount
$129,290 quoted

What equipment and installation scope was quoted?

Original proposal configuration
ItemQuoted value
PV modules60 JinkoSolar JKM425N-54HL4 panels at 425 W, for 25.5 kW DC.
Modeled orientations24 modules at 81° azimuth with a 30° slope; 36 at 180° with a 28° slope. Tilt racks were listed for 36 panels.
InvertersTwo EG4 FlexBOSS21 units with 32 kW combined inverter rating listed. This is not a verified export or backup limit.
StorageFour EG4 PowerPro WallMount modules at 14.3 kWh each. No final reserve, load schedule or runtime confirmed.
Cash quote$129,290 gross, valid through May 4, 2025. The optional utility smart meter was excluded. No verified signed acceptance, payment, or final equipment list.

The archived quote contains a 2025 incentive calculation. That illustration is not verified eligibility, money received or a lower project cost. The gross quote is shown instead.

What does the full 12-month model say?

The source lists 33,102 kWh estimated annual generation against 63,791 kWh estimated annual consumption, about 52% as an energy ratio. That is not a share of outage hours or a claim that the bill falls by 52%.

Source table: rounded monthly figures, not meter readings
MonthDaily PV (kWh/day)PV output (kWh)Use before (kWh)Grid imports (kWh)Export (kWh)Export creditBill beforeBill afterCumulative energy creditPrinted savings
Jan63.51,9705,8323,9291$0$679$504$0$175
Feb70.21,9656,2404,3293$0$733$551$0$183
Mar83.32,5844,8802,603222$6$571$345$0$226
Apr1033,0973,7691,365586$16$464$209$0$256
May1314,0574,5181,332727$20$552$162$0$390
Jun1083,2495,6042,54991$3$684$370$0$313
Jul1163,5826,6463,20944$1$805$383$0$423
Aug95.72,9656,5413,66912$0$793$494$0$299
Sep91.62,7475,7663,12016$0$703$434$0$269
Oct89.62,7764,4261,946184$5$541$293$0$248
Nov69.22,0764,2092,23517$0$496$309$0$187
Dec65.62,0335,3593,3980$0$626$442$0$184
Sum of rowsNot additive33,10163,79033,6841,903$51$7,647$4,496Not additive$3,153

The summed generation and assumed use differ from the printed annual summaries by 1 kWh each. Rounded bill columns can also differ from the savings column. The cumulative energy credit is not another cash payment or a sum of bill savings.

Why did the model keep a utility bill?

The source uses a location-based residential tariff with seasonal energy rates and a separate peak-demand charge. Energy generated over the year does not remove fixed charges or prove the battery will lower the highest demand at the times that set the charge.

Historical assumptions and remaining gaps
InputWhat the model specified
Energy rates$0.11/kWh in summer and $0.10/kWh in winter; modeled export credit $0.03/kWh.
DemandThe modeled seasonal schedule charged $8.00/kW in defined peak windows and $0/kW off-peak. The source did not have an account-confirmed rate.
Fixed chargesSource lists a $14.50/month fixed charge and $0.97/month base charge.
Technical forecastSystem Advisor Model 2020.02.29.r2; 15.8% total losses, 3.1% inverter losses and 2.1% shading losses as modeled.
Long-term bill modelThe source reports $92,309 modeled lifetime savings under its assumptions, including 4% annual price growth, and does not tabulate unlabeled annual plot values. No actual savings, current rates or payback verified.

This was a quote, not a verified sale or installation. No account bills, actual electric demand, payment, final monitoring data or approved photos were available. Location is withheld.

Ask how a quote handles peak demand

Start with actual bills and a time-of-day load profile. Then ask what the battery is designed to support, what the utility uses to measure demand and what the quoted equipment will cost before any assumed incentives.

Request a home solar assessment

Source: Anonymized The Solar Roofers site-specific proposal, valid through May 4, 2025, including equipment and the original performance and tariff tables.