The Solar Roofers · Historical design example

810 kW commercial-scale solar proposal

The original estimate priced a 1,500-module system at $1,782,000. Its engineering inputs and modeled energy are useful. The cost-saving projections are not reliable without the correct utility tariff.

Historical cash quote
$1,782,000
Proposed DC rating
810.0 kW
Proposed AC inverter rating
600 kW

Original estimates describe proposed work. They do not establish an installation, payment, actual production, or current pricing. Property and customer identifiers have been removed.

What the original quote covered

Equipment in the archived cash quotation
ItemQuoted design
Solar generation capacity1,500 Jinko JKM540M-72HL4-V modules at 540 W each, 810.0 kW DC.
InvertersTen Sol-Ark 60K-3P-480V units, 600 kW aggregate inverter rating. DC and AC ratings are not interchangeable.
Quoted array arrangementTwo 75-module sections at 124° and sections of 300 and 1,050 modules at 126°, each on a 9° slope.
Cash quotation$1,782,000 for the listed system. An installed retailer smart meter, if requested, was separate. Validity ended December 6, 2025.
Storage and approvalsNo battery system is included in the listed quote. Structural findings, demand study, any approved export arrangement, and installation completion were not verified.

This archived option was identified to a specific commercial-sized property. The published example omits the site and organization identifiers. It is a proposed equipment design, not a build, utility approval, or bill analysis.

Production and bill model

The proposal estimates 1,170,699 kWh/year generated and 692,660 kWh/year used, about 169% when comparing annual totals. Monthly net surplus is not measured power exported at any hour. An actual large system needs account-specific demand, service and utility export analysis before drawing that conclusion.

Proposal’s monthly forecast generation and its estimated load (kWh)
Forecast generationEstimated load
033,00766,01499,020132,027JanFebMarAprMayJunJulAugSepOctNovDecJan: 58,164Feb: 62,447Mar: 82,324Apr: 118,734May: 132,027Jun: 129,937Jul: 127,845Aug: 126,251Sep: 105,021Oct: 96,507Nov: 69,478Dec: 61,965Jan: 40,000Feb: 60,000Mar: 48,160Apr: 52,000May: 60,000Jun: 65,000Jul: 55,000Aug: 80,000Sep: 70,000Oct: 62,000Nov: 52,000Dec: 48,500
Source model: estimated monthly net energy balance (kWh)
Source net energy balance
−72,845−55,246−37,646−20,046−2,447JanFebMarAprMayJunJulAugSepOctNovDecJan: −18,164Feb: −2,447Mar: −34,164Apr: −66,734May: −72,027Jun: −64,937Jul: −72,845Aug: −46,251Sep: −35,021Oct: −34,507Nov: −17,478Dec: −13,465
Exact monthly model values as printed; the bill calculation is unverified
MonthForecast solar (kWh)Source load (kWh)Modeled net energy (kWh)Model bill beforeModel bill afterPrinted cumulative creditPrinted difference
Jan58,16440,000−18,164$5,979$16$2,713$5,963
Feb62,44760,000−2,447$8,956$16$3,086$8,940
Mar82,32448,160−34,164$7,194$16$8,180$7,178
Apr118,73452,000−66,734$7,765$16$18,123$7,749
May132,02760,000−72,027$8,982$16$28,877$8,966
Jun129,93765,000−64,937$10,633$16$39,484$10,617
Jul127,84555,000−72,845$8,999$16$51,383$8,983
Aug126,25180,000−46,251$13,084$16$58,937$13,068
Sep105,02170,000−35,021$11,425$16$64,640$11,409
Oct96,50762,000−34,507$9,254$16$69,785$9,238
Nov69,47852,000−17,478$7,765$16$72,396$7,749
Dec61,96548,500−13,465$7,244$16$0$7,228

Energy inputs: System Advisor Model 2020.02.29.r2, 16.7% system losses, 3.5% inverter losses, 0% shaded or optimizer losses and no performance adjustment, as printed. The twelve rows sum to 1,170,700 kWh of production, 1 kWh above the 1,170,699 kWh cover headline, and 692,660 kWh load, consistent with the proposal.

The archived tariff assumptions were residential summer rates of $0.13 and $0.14/kWh, winter rates of $0.13 and $0.12/kWh, $0.03/kWh adjustment, $14.50 monthly fixed charge plus $1.50 NDR, 4% price escalation and a 6.75% financial discount rate. They are included to show why the projected dollars do not belong in a commercial investment decision.

Original terms and what remains unverified

Financial model withheld as a recommendation. The source applies a residential utility rate to a commercial-sized 600 kW AC configuration. The account tariff and export methodology were not confirmed. The after-solar model repeats a $16 bill monthly and resets the printed cumulative credit from $72,396 in November to $0 in December without explanation. Don’t treat any credit, savings, payback, or modeled financial chart as applicable to a real bill.

The original includes 20-year projections, but the underlying financial assumption must first be corrected against the actual tariff and export agreement. None of its financial outcomes has been relied on here. The archive listed 12-year panel product, 25-year panel performance and 10-year inverter warranty language, which does not establish current warranty availability.