The Solar Roofers · Historical design example

22.1 kW home solar and EG4 battery proposal

The archived design paired 52 panels and three batteries for a household using about 48,500 kWh a year. Its forecast covers about 58% of annual energy use, not 58% of every power bill.

Original system quote
$96,330
Proposed array
22.1 kW DC
Listed storage
42.9 kWh

Original estimates describe proposed work. They do not establish an installation, payment, actual production, or current pricing. Property and customer identifiers have been removed.

What the original quote covered

Quoted equipment and mounting
ComponentArchived proposal
Array52 Jinko Solar JKM425N-54HL4 modules at 425 W each, 22.1 kW DC. Three 28° planes: 17 modules at 205°, 17 at 115°, 18 at 295°.
InverterEG4 FlexBOSS21, listed at 16 kW output in the archived design.
Backup storageThree EG4 PowerPro WallMount batteries at a listed 14.3 kWh each, 42.9 kWh combined on the quote.
MountingRoof-mounted design; black end-fastening system, 24 UFO-END-01-B1 end fasteners in scope.
System price$96,330 quoted. The estimate is not a signed contract; no payment or start of work verified.

The east- and west-oriented roof sections extend generation beyond one midday-facing plane. The proposal describes battery use after sunset and grid supply when solar and storage are insufficient. It does not provide a measured backup runtime or prove that every home circuit would be powered.

Production and bill model

The model predicts 28,150 kWh of PV generation against 48,538 kWh of annual household use, about 58%. The monthly table prints 21,262 kWh of modeled net grid energy; that field includes model effects beyond generation subtracted from use and is reproduced as the source labels it.

First-year solar generation and household use (kWh)
Forecast generationSource household use
01,2592,5183,7775,036JanFebMarAprMayJunJulAugSepOctNovDecJan: 1,360Feb: 1,807Mar: 2,392Apr: 2,788May: 2,957Jun: 3,241Jul: 3,155Aug: 3,000Sep: 2,357Oct: 2,271Nov: 1,541Dec: 1,281Jan: 4,808Feb: 4,296Mar: 3,571Apr: 3,168May: 3,142Jun: 4,123Jul: 5,034Aug: 5,036Sep: 4,529Oct: 3,521Nov: 3,251Dec: 4,059
Modeled bills before and after solar and storage
Bill beforeBill after
$0$136$273$410$546JanFebMarAprMayJunJulAugSepOctNovDecJan: $524Feb: $472Mar: $400Apr: $360May: $357Jun: $455Jul: $546Aug: $546Sep: $496Oct: $395Nov: $368Dec: $449Jan: $390Feb: $297Mar: $169Apr: $90May: $72Jun: $142Jul: $240Aug: $256Sep: $268Oct: $178Nov: $221Dec: $325
Reported monthly bill difference
Reported difference
$0$78$156$235$313JanFebMarAprMayJunJulAugSepOctNovDecJan: $133Feb: $175Mar: $231Apr: $269May: $285Jun: $313Jul: $306Aug: $290Sep: $228Oct: $218Nov: $148Dec: $124
Exact first-year monthly model as printed; annual line as shown in the proposal
MonthForecast solar (kWh)Source usage (kWh)Modeled net grid (kWh)Bill beforeBill afterDifference as printed
Jan1,3604,8083,471$524$390$133
Feb1,8074,2962,537$472$297$175
Mar2,3923,5711,255$400$169$231
Apr2,7883,168466$360$90$269
May2,9573,142281$357$72$285
Jun3,2414,123982$455$142$313
Jul3,1555,0341,970$546$240$306
Aug3,0005,0362,130$546$256$290
Sep2,3574,5292,244$496$268$228
Oct2,2713,5211,339$395$178$218
Nov1,5413,2511,770$368$221$148
Dec1,2814,0592,817$449$325$124
Printed annual28,15048,53821,262$5,368$2,648$2,720

Historical model inputs: Meriwether Lewis Electric Cooperative residential rate with $0.08/kWh energy, $0.02/kWh fuel adjustment, $45.50 monthly fixed charge and $1.54 monthly hydro credit. The source assumes 4% annual energy-price escalation, 6.75% financial discount rate, 15.0% system losses, 3.1% inverter losses, and 0% optimizer and shade losses. These are source assumptions, not a current tariff quote.

Original terms and what remains unverified

The 25-year financial table starts at $1,854 in projected calendar-year savings for 2026; the distinct first-year monthly model prints $2,720. The archive does not reconcile the difference. Its $77,208 lifetime bill saving and −$19,122 ending net position are modeled, not a return claim or payback date.

Printed 25-year model: net position after initial quoted cost
Net position as printed
−$94,476−$75,638−$56,799−$37,960−$19,122202620312036204120462050
Exact annual line items from the source financial projection
YearReported annual savingReported cumulative net position
2026$1,854−$94,476
2027$1,928−$92,548
2028$2,005−$90,543
2029$2,085−$88,457
2030$2,169−$86,289
2031$2,256−$84,033
2032$2,346−$81,687
2033$2,440−$79,248
2034$2,537−$76,710
2035$2,639−$74,072
2036$2,744−$71,327
2037$2,854−$68,473
2038$2,968−$65,505
2039$3,087−$62,418
2040$3,210−$59,208
2041$3,339−$55,869
2042$3,472−$52,397
2043$3,611−$48,786
2044$3,756−$45,030
2045$3,906−$41,124
2046$4,062−$37,062
2047$4,225−$32,837
2048$4,394−$28,444
2049$4,569−$23,874
2050$4,752−$19,122

The source described two-year workmanship coverage limited to roof-mounted work, separate electrical coverage, a 15-year module product term, a 30-year module performance term and 10-year inverter and battery terms. Confirm current warranties separately. The estimate excluded structural assessment and did not verify whether permit fees, meter work, utility approval or final electrical terms would be included in a signed contract. There is no verified as-built or site-photo evidence in this archive.

Source basis: archived five-page residential estimate. Page 1 lists design and price, page 2 contains model charts, page 3 provides both tables and assumptions, pages 4–5 contain terms. The photograph-free presentation does not suggest this was built.

The Solar Roofers · Site-specific designs

Compare a design for your own property

Start with a year of usage, the roof or ground space, and the equipment you want to run during an outage.

Talk with the solar teamSee more design examples