Rockvale, Tennessee · Preliminary solar and battery estimate

A Rockvale proposal for 55 solar panels and 28.6 kWh of battery storage

How much solar can you put on one existing structure before you need another roof? This Rockvale estimate proposed 55 panels on the available rear structure, alongside two hybrid inverters and two batteries. The $103,982.50 price was an estimate. The source gives a preliminary offset figure, but not the usage and production data needed to check it.

Modules quoted for the existing structure
55 panels
Combined quoted EG4 storage
28.6 kWh
Gross March 2025 estimate
$103,982.50

What was included in the Rockvale quote?

The design notes say the existing rear structure had room for the quoted array but not for additional panels. The sales team discussed a possible future outbuilding and a garage concept that would provide less power. Neither concept is a priced second array in this estimate.

Equipment and installation materials listed in the source
Scope itemWhat the document identifies
Solar modules55 Qcells Q.BOOST ML-G2 405 W modules, or equivalent. If all selected modules were exactly 405 W, that would be 22.275 kW DC. No final module model or final as-built capacity is verified.
Hybrid invertersTwo EG4 18kPV-12LV inverters. The quote lists up to 18 kW of PV input per inverter as an equipment rating, not as this array's size or output.
Battery storageTwo EG4 PowerPro WallMount batteries rated at 14.3 kWh each; 28.6 kWh combined. The quote discusses the ability to add capacity later. No final backup duration or isolated-circuit list is attached.
Mounting and electrical scopeMounting and fastening hardware, electrical wiring and conduit, disconnects and specified safety equipment.
Control and support notesThe estimate describes a reserve setting to keep stored energy available ahead of storms and company monitoring. It does not provide detailed controls, service fees or executed support terms.

The contractor's project manager or master electrician was to complete a site survey before contract. That visit was intended to confirm the actual equipment locations, electrical work and remaining installation questions. The estimate noted the crew was two to four weeks out at the time, not a promised installation or completion date.

What was the price before any assumed incentive?

The two-page estimate gives a gross system price of $103,982.50. It does not show a signed acceptance, invoice payment, deposit or equipment-by-equipment price. The prospect record had no invoices.

The original worksheet showed an illustrative 2025 incentive assumption of $31,194.75 and subtracted it to display $72,787.75. That is historical quote arithmetic, not a verified net price, an incentive actually obtained, or a statement about eligibility today.

How much energy was the 55-panel Rockvale design projected to offset?

The March 21, 2025 production model estimated 64% annual energy offset. It used 48,910 kWh of estimated yearly household electricity use. The sum of printed solar-generation rows is 31,385 kWh. This supports the proposal’s preliminary expectation of at least 60%, but it does not verify the homeowner’s historical usage, actual output, or outage coverage.

Typical day by month (kWh/day)

050100150200JanFebMarAprMayJunJulAugSepOctNovDec
Teal: the 12 printed daily solar estimates. Gold: estimated daily use derived from the rounded monthly use divided by days in the month.

Solar production and grid flows by month (kWh)

01,0002,0003,0004,000JanFebMarAprMayJunJulAugSepOctNovDec
Teal: generated by solar. Navy: imported from grid. Gold: exported to grid. This is the planning model, not a record of delivered power.

Estimated utility bill by month

$0$150$300$450$600JanFebMarAprMayJunJulAugSepOctNovDec
Navy: modeled before solar. Teal: modeled after solar. The source rounded each month to whole dollars.

Average monthly bill in the original model

$0$100$200$300$400$500$600BeforeAfter
Both bars preserve their relative height from the source. The model did not print a dollar amount above each bar. The original monthly numbers are below.
All 12 monthly rows from the March 2025 Rockvale model
MonthSolar produced (kWh)Home use (kWh)Grid import (kWh)Grid export (kWh)Export credit ($)Bill before ($)Bill after ($)Reported savings ($)Daily solar (kWh/day)
Jan1,6654,8283,388194450735914853.7
Feb2,1164,3132,682444845528317275.6
Mar2,7323,5861,7888771638218619688.1
Apr3,0393,1811,4021,19822341141200101
May3,0453,1551,2041,0251833912421498.2
Jun3,3224,1401,80792117438187251111
Jul3,2255,0552,49459711530262268104
Aug3,2035,0572,51959411530264266103
Sep2,6784,5482,4715431047926021889.3
Oct2,7453,5351,7649071637718319488.6
Nov1,9463,2641,851478935019915164.9
Dec1,6694,2472,950328644831213653.8
Sum of rounded rows31,38548,90926,3208,1061485,1762,7602,414Not summed

The estimated use total set by the model is 48,910 kWh. Its displayed monthly inputs sum to 48,909 kWh after rounding. Credits, bills, and savings are separate printed columns; sums of rounded values need not reconcile exactly. The quote and model do not certify what this system actually produced.

Which design and utility assumptions went into these numbers?

  • Roof and layout: 42 panels on a 30° slope and 13 panels on a 20° slope, all modeled at 143° azimuth. The quote used 405 W panels or equivalent (22.275 kW DC if all 55 panels were 405 W); the final panel choice is not verified.
  • Model inputs: System Advisor Model 2020.02.29.r2, 13.3% overall losses, 3.1% inverter losses, 1.5% optimizer losses, 2.5% modeled shade and 0% performance adjustment. The parts list priced two 14.3 kWh EG4 batteries, but the source does not give a verified backup-load schedule.
  • Rates assumed in 2025: the simulator selected Middle Tennessee Electric residential service with the DPP export scenario. It showed $0.08/kWh base energy, $0.02/kWh modeled fuel adjustment, a $0.02/kWh export credit as displayed, and $21.81/month fixed. No customer tariff was supplied. It assumed a 4.0% annual energy-cost increase.

64% offset does not mean a 64% lower bill or 64% backup. The model showed utility imports every month and low-priced exports even in months when the home still drew power from the grid. The original decision about when to keep energy in reserve for storms depended on operating settings, selected backup loads, and site verification.

Do the modeled bill savings show when the project would pay for itself?

No. The original visible utility chart estimated $72,479 in utility-bill savings over 20 years. That is a forecast of the electricity bills, not an all-in return. The $103,982.50 gross quote and the separate historical incentive illustration above are scope pricing; neither verifies an amount actually paid or a credit received.

The visible forecast does not establish a break-even date. Financing and operating costs, utility rate changes, actual equipment costs, and eligibility for any incentive would all affect that calculation. Compare the documented gross quote and the utility projection separately.

Cumulative utility-bill savings (20-year model)

$0k$20k$40k$60k$80k15101520$72,479
The five stacked bars preserve the original chart shapes. Only the full year-20 savings of $72,479 is printed; intervening bar heights are not exact labeled dollars.

If your preferred roof cannot fit the entire array, ask the designer to compare the current roof with a second structure or a ground mount before finalizing the quote. A larger layout only helps if the additional area, connecting route, and electrical design are suitable.

Sources: the original March 21, 2025 itemized estimate and its attached four-page system model, recorded with the same Rockvale proposal. They are one scope, not two customer cases. The original documents contain no signed acceptance, paid invoice, installed production or verified realized savings.

What the existing roof looked like

Close-up of the existing light-gray ribbed metal roof surface.
Existing metal roof surface shown in a site-planning photo uploaded March 21, 2025. No solar panels are shown.