Nashville, Tennessee · Closed roof-and-solar project

A standing seam roof and 29.7 kW solar design in Nashville

The signed design paired a standing seam roof project with 66 REC solar panels, 66 Enphase microinverters and a FranklinWH battery system. This case shows the actual equipment choices and why a roof-and-solar quote has to distinguish the roof, array, controls and storage.

Solar array nameplate, DC
29.7 kW
REC Alpha Pure-RX panels in signed design
66 panels
One Enphase microinverter for each panel
66 microinverters

What equipment did this roof-and-solar agreement specify?

Equipment from the signed project design
ComponentSpecified equipmentRole in the system
RoofStanding seam metal roofing in the documented job scope.The roofing and solar were part of the same project record. The source does not document every field attachment or roof penetration.
Solar panels66 REC450AA PURE-RX (REC Alpha Pure-RX HJT) modules, 450 W each.66 × 450 W = 29,700 W DC at nameplate conditions. That is array size, not annual energy or percent offset.
Microinverters66 Enphase IQ8X-80-M-US units, listed at 384 VA apiece.One unit per panel; the sum of their listed nameplates is 25.344 kVA AC. That is not a measurement of export or energy production.
Array controlEnphase IQ Combiner 5 with Envoy.The documented Enphase component for combining and communicating with the solar equipment.
RackingIronRidge XR100.The signed design identified the rails. It does not independently establish the final roof attachment layout.
Storage and controlsFranklinWH aPower 2 and aGate X (V2).The storage family and control equipment are documented. The battery count and total capacity conflict in the records, so neither installed figure is stated here.

What had to be coordinated between the roof and the solar system?

The signed design and billing records name several distinct work packages. These packages explain how the scope was divided; they are not a dated log of the crew's actions or proof that every approved item was installed exactly as initially specified.

  1. Standing seam roofing and array layout. A quote for both trades should say who is responsible for the roof, how the rack attaches, and what roof details must be kept clear. This job records the roof type and rack family, not a complete as-built mount layout.
  2. Module-level conversion. The signed schedule pairs each of the 66 modules with its own Enphase microinverter rather than listing one central PV inverter for the array.
  3. Array communications, a battery bank and its control equipment. The signed list specifies components from Enphase and FranklinWH. The storage configuration is a separate part of the total system, which should be verified before making backup-duration or whole-home coverage claims.
  4. Commissioning and the utility milestone. The invoices include a milestone named for commissioning and utility approval. An invoice line is not an independent utility authorization, inspection report, or monitoring history.

For comparable bids: Request separately identified roof, panels, battery, electrical work and utility-related scope. Two quotes with the same array rating might cover very different work.

What can we say about the price and performance?

Project evidence and its limits
RecordWhat it establishes
Project statusThe project is closed in the company records. The signed solar agreement confirms the design and equipment listed above.
Billing detailBilling records include roofing and PV deposit, progress payments, additional battery work and a commissioning/utility milestone. The documents reviewed do not reconcile to one independently verified whole-project or solar-only total, so no price is presented.
StorageFranklinWH equipment is specified; installed battery count, exact kWh, backed-up load coverage and outage runtime remain unverified.
Utility and outputNo independent utility permission to operate, monthly production chart, consumption chart, meter data, or bill savings was verified from these records.
PhotosNo verified, anonymized images from this exact job are shown. Images from another Franklin or Nashville project would not document this site.

If you're replacing a roof before adding solar, ask for the roof specification, solar scope and storage scope on the same written proposal, with clear responsibility for installation and later service.

Ask about a Nashville roof and solar quote

Source: Anonymized The Metal Roofers signed PV agreement and closed-job billing records. Equipment is shown as specified, not as independently inspected. No price or measured output is presented.

A separate 45.15 kW solar and Tesla storage proposal

Another version in this project file specified 105 Qcells 430 W modules and 10 Tesla batteries totaling 135 kWh as written. The proposal body and its payment schedule give $180,500. A separate $180,140 line appears elsewhere in the PDF, so the two figures have not been reconciled. This is not evidence that the larger configuration was installed or paid for, and the existing 29.7 kW scope remains separate.

Milestones from the older $180,500 schedule
MilestoneQuoted payment
Deposit (60%)$108,300
Installation start (20%)$36,100
Installation completion (15%)$27,075
Commissioning (5%)$9,025

Other quoted house and barn scopes in the same project

The project archive contains separate roof, main-house solar and possible barn work documents. These six versions belong to the same Nashville property. They are not independent customers, amounts to add to the signed document, or work verified as completed. The older 45.15 kW proposal remains separate above.

Four main-house estimate or agreement documents
Source versionWritten scopeWhat the source says about price
Earlier bundled roof and solar estimate, May 2025Standing seam roof section, plus 70 Jinko JKM425N-54HL4-B 425 W modules (29.75 kW), 70 Enphase IQ8PLUS-72-M-US units and four 15 kWh FranklinWH aPower 2 batteries (60 kWh listed).Roof: $71,950; solar: $82,800. The printed sections add to $154,750; not a verified single invoice.
Later bundled revision, May 2025Same printed roof line and 29.75 kW Jinko/Enphase equipment schedule with 60 kWh of listed FranklinWH storage.Roof: $71,950; solar: $109,475. The sections add to $181,425. Solar line differs by $26,675; source does not reconcile why.
Earlier PV-only agreement form, May 202566 REC Alpha Pure-RX 450 W modules (29.70 kW), 66 Enphase IQ8X microinverters and five 15 kWh aPower 2 batteries (75 kWh listed).$133,140 on the schedule; $135,140 in the itemized section. The three printed payments total $133,860; no fully reconciled earlier price.
Updated PV agreement copy, September 2025Same 29.70 kW REC/Enphase array. Lists six aPower 2 units at 15 kWh each but prints 75 kWh total. Four additional panels are listed as made available only, with no mounting, wiring, permitting or integration.$180,140 printed in this signed PV document and its payment schedule. Verified as the stated figure in this document only, not the combined property price, paid balance, or scope of a barn install.

May PV form: $93,918, $33,285 and $6,657 are the amounts shown. September signed PV copy: $126,098, $45,035 and $9,007 are specified (70%, 25%, 5%) and sum to $180,140. A milestone schedule is not a receipt. Because six times 15 is 90 kWh while that copy reports 75 kWh, the actual storage configuration and any commissioned capacity remain unverified.

Two potential barn designs, not evidence of a barn installation

Separate archived barn scopes
SourceEquipment and workGross figure and limitations
Barn Tesla form66 Qcells 430 W panels, 28.38 kW DC. Detail text lists two Tesla Powerwall 3 base units and four Powerwall expansions (81 kWh combined as stated). Its storage heading instead names FranklinWH, so final equipment must be checked.$135,000 quoted. Milestones shown: $81,000, $27,000, $20,250 and $6,750. No separate model or independently verified acceptance, installation or payment.
Barn PV plus FranklinWH estimate60 Qcells Q.TRON BLK M-G2+ EnFin modules and 60 Enphase IQ8X-80-M-DOM-US microinverters. Five FranklinWH aPower 2 units, approximately 75 kWh as listed. Racking, trenching and about 260 linear feet of 6-inch K-style gutters shown in scope. Exact module wattage not identified in the quoted line item.$139,850 gross, explicitly nonbinding. The model later uses a different cost basis that does not match the quote; it is not a second price or verified rate of return.

The separate barn estimate is the only one of these six files with a full monthly production-and-utility table. The model uses estimated annual consumption of 32,000 kWh, about 124% production-to-use, and 60 modules at 200° azimuth with 28° tilt. The usage basis is a forecast input, not independent meter history. It does not belong to the main house or the Tesla barn form.

Barn PV plus FranklinWH option: modeled solar production and estimated use (kWh)
Forecast PVEstimated use
01,0302,0603,0894,119JanFebMarAprMayJunJulAugSepOctNovDec
Barn PV plus FranklinWH option: modeled grid imports and exports (kWh)
ImportsExports
04168321,2471,663JanFebMarAprMayJunJulAugSepOctNovDec
Barn PV plus FranklinWH option: model bills before and after (USD)
BeforeAfter
$0$97$194$290$387JanFebMarAprMayJunJulAugSepOctNovDec
Exact monthly barn figures and arithmetic totals of displayed rows
MonthForecast PV (kWh)Estimated use (kWh)Modeled imports (kWh)Modeled exports (kWh)Model export creditModel bill beforeModel bill afterDifference as printed
Jan2,1293,1591,264102$2$360$154$205
Feb2,6942,822601334$6$324$79$245
Mar3,3892,34674961$17$272$18$254
Apr3,7742,08181,572$28$240$18$221
May3,8482,06401,663$30$238$18$220
Jun4,1192,709131,278$23$321$18$302
Jul4,0503,307151721$13$387$24$363
Aug4,0303,309129662$12$387$23$365
Sep3,3162,976323500$9$350$47$303
Oct3,4982,313641,135$20$264$18$246
Nov2,4862,136336521$9$245$46$199
Dec2,2062,779938285$5$319$116$203
Sum of displayed rows39,53932,0013,9019,734$174$3,707$579$3,126

The original barn model used System Advisor Model 2020.02.29.r2, 11.4% system losses, 3.5% inverter losses, no optimizer/shading/performance adjustment, and 4% annual electricity-price escalation with a 6.75% discount input. It names a residential rate scenario of $0.11/kWh energy, $0.02/kWh modeled export credit and $20.34 fixed monthly. Some printed post-solar bills are $18 and the displayed $174 export credit does not reconcile to the stated rate multiplied by displayed export volume. The $92,493 20-year endpoint and differing cost input are not verified utility results or proof of an incentive.

Evidence basis: two May roofing-and-solar estimates, the May PV form, the September signed PV copy, and the two barn quote files. Only the separate barn PV plus FranklinWH PDF supplies the exact model above. No finished barn photo, completed work, utility approval, settled payment, installed battery quantity, or metered production is established by these files.

A closer look at the roof detail

This photo was added March 18, 2026, to the roof-and-solar job record. It is a roof detail, not a solar closeout photo.

Close-up of metal roof panels at a brick-wall junction
Metal roof panels at the brick-wall junction, as documented in the roof-and-solar job photo album. No solar modules are visible here.