Nashville, Tennessee · Commercial proposal · Modeled results

A 59.94 kW Nashville commercial solar and battery proposal

Why does a 111-panel commercial array cover about half of this property's modeled annual use? This Nashville design projected sharply higher winter electricity use. The $149,985 proposal sized a 59.94 kW array and 42.9 kWh of battery storage for the site. Its 49% generation-to-use estimate is a design result, not confirmed savings or installed output.

Proposed commercial array
59.94 kW DC
Combined quoted EG4 storage
42.9 kWh
Historical cash quote
$149,985

What did the 111-panel proposal include?

The scope calls this the largest array the proposal could implement on the property. That is the source’s design boundary, not a verified structural, permitting or utility limit.

Equipment and scope from the archived quote
ItemWhat was specified
Photovoltaic modules111 Jinko JKM540M-72HL4-V 540 W modules; total 59.940 kW DC.
InvertersFive EG4 FlexBOSS21 units. The source lists 16 kW per inverter with solar present and 80 kW combined rating. This is not the array’s DC size or a guaranteed backup or export limit.
StorageThree EG4 PowerPro WallMount batteries at 14.3 kWh each, totaling 42.9 kWh as quoted.
Included scopeMounting and racking, labor and electrical work, testing and commissioning, permit/inspection coordination, and coordinating utility interconnection as specified. Charged jurisdiction fees were separate unless included in writing.
Proposed price$149,985 gross, valid through August 19, 2026 in the source. No verified payment or signed acceptance.

The proposal listed two years of workmanship coverage, historical panel terms of 12 years for product and 25 years for performance, and 10-year manufacturer terms for inverters and batteries. They are source terms, not verification of current eligibility. The historic estimate separately assumes an illustrative $44,995.50 incentive and displays $104,989.50 after that assumption; no actual incentive or eligibility is established.

What did the proposal model month by month?

The annual model lists 62,192 kWh generation versus 128,000 kWh use, 86,438 kWh imported after solar and storage, and 19,933 kWh exported. January and February have the two highest load estimates, while June and July show strong production and modeled exports. Storage does not itself create more annual solar generation.

Estimated generation and business use (kWh)

06,00012,00018,00024,000JanFebMarAprMayJunJulAugSepOctNovDecModeled productionEstimated business use
Both series use the exact printed monthly kWh table below; an annual ratio does not show hourly self-consumption.

Modeled monthly electricity bill (USD)

$0$700$1,400$2,100$2,800JanFebMarAprMayJunJulAugSepOctNovDecBefore proposed systemAfter proposed system
These are projected bills, not utility statements or a promise of bill savings.
First-year modeled figures, as printed in the proposal
MonthSolar generation (kWh)Estimated use (kWh)Imports after (kWh)Exports after (kWh)Export creditBill beforeBill afterEstimated savings
Jan2,19318,00015,8070$0$1,955$1,719$236
Feb3,27624,00020,7240$0$2,600$2,248$352
Mar5,0209,5005,6681,120$20$1,041$609$432
Apr6,6149,0004,9292,470$44$968$495$473
May7,5978,5003,9732,982$54$917$386$531
Jun8,7909,0004,1163,820$69$1,019$408$611
Jul8,3097,0002,9014,121$74$797$268$529
Aug7,3609,2004,6482,720$49$1,041$487$554
Sep5,2918,0004,3651,580$28$906$475$431
Oct4,0326,8003,9031,058$19$737$412$324
Nov2,2997,0004,81462$1$758$527$232
Dec1,41012,00010,5900$0$1,310$1,158$152
Reported annual totals; bill columns summed62,192128,00086,43819,933$358$14,049$9,192$4,857

How to read the model: The source shows 62,192 kWh annual generation; rounded months sum to 62,191 kWh. The before/after bill totals $14,049 and $9,192 are sums of printed months, not printed annual figures. The $358 printed export credit does not reconcile to 19,933 kWh at the displayed $0.02/kWh ($398.66). The tariff label is for an under-500-kWh class while the proposal is for a business modeling at least 6,800 kWh every month. No actual commercial rate, demand charge treatment or precise credit calculation is established.

Which assumptions drive the estimates?

Technical and tariff inputs printed in the source
Model inputWhat the proposal used
Array layoutAll 111 modules modeled at azimuth 50° and tilt 28°.
Model setupSystem Advisor Model 2020.02.29.r2, total losses 19.7%, inverter loss 3.2%, shade and optimizer losses 0%, performance adjustment 0% as modeled.
Tariff assumptions, not account factsNashville Electric Service under-500-kWh DPP model label: $0.11/kWh use, $0.02/kWh displayed export credit, $20.34 fixed per month. Commercial account tariff not verified.
Financial assumptions4% annual electricity price growth; 6.75% discount rate; replacements outside warranty not included.

The proposal prints $136,010 projected lifetime utility-bill savings, or $13,975 less than the gross quoted price. This is the original model, not a validated return. For a business, verify the account tariff, demand billing and treatment of excess exports before comparing system costs with financial returns.

Cumulative modeled utility-bill savings

$0$28,000$56,000$84,000$112,000$140,00015101520Year 20: $136,010Years in archived model
The shape follows the original proposal’s vector plot. Only the 20-year endpoint was printed, so there are no inferred annual dollar figures.

What this quote does and does not establish

The document establishes an original design and quoted contractor scope for a distinct property. No authorized signature, invoice payment, completed installation, interconnection approval, operating data or measured savings were verified. Private property and customer references are omitted.

Ask for a site-specific solar quote

Source: Anonymized ten-page The Metal Roofers commercial solar and storage proposal. Equipment, pp. 1–4; generation and finance assumptions, p. 5; first-year table, p. 6; tariff, quote and source vector curve, p. 7; historic financial illustration and terms, pp. 8–10.