Nashville, Tennessee · Site-specific unsigned proposal

A 5.1 kW Nashville solar proposal with two EG4 batteries

This proposal specified 12 Jinko modules and 2 EG4 batteries for a Nashville property. The quoted price was $31,820. The designer did not have the property's bills, so the financial and consumption forecasts used a 14,940 kWh placeholder, not the home's measured electrical use.

12 × 425 W solar modules
5.1 kW DC
2 × 14.3 kWh EG4 storage units
28.6 kWh nominal
Proposed system cost, not a payment
$31,820 quoted

What was included in the proposed system?

Project-specific quote equipment
ItemProposed detail
Solar array12 JinkoSolar JKM425N-54HL4 N-type modules at 425 W each, 5.1 kW DC. One preliminary roof orientation, azimuth 149° and slope 20°. A site survey would confirm final layout.
Hybrid inverterOne EG4 FlexBOSS21. The quote lists 16 kW continuous output. Final load coverage or available export power was not established.
Battery storage2 EG4 PowerPro WallMount units at 14.3 kWh each, 28.6 kWh total by the equipment list. No usable backup duration or backed-up load schedule was established.
Racking and electricalThe proposal listed 22 black UFO-END-01-B1 end-fastening components, roof mounting and related electrical work through a licensed electrical partner.
Quoted price and work$31,820 for the stated solar and battery scope, not a paid or signed sum. Roof repair or reinforcement and permit fees were not included unless specified. Permitting, utility coordination and final equipment locations still needed confirmation.

The estimate describes separate equipment warranties and a two-year workmanship term for its roof-mounted work. The pricing document is not a signed warranty or an operating guarantee.

Why did the proposal need actual utility bills?

The quote was designed around a modest rooftop array and two storage units. A household that shifts its use into the afternoon, or runs a high overnight load, can see a different outcome even with the same panels. A full year of utility use is one of the first checks before relying on a bill projection.

Year-one source model; placeholder consumption, no actual bills
MonthGeneration (kWh)Assumed use (kWh)Bill beforeBill afterPrinted savings
Jan3761,475$179$139$40
Feb4871,318$162$111$51
Mar6321,095$138$72$66
Apr716972$123$50$72
May735964$122$47$75
Jun8041,265$161$74$87
Jul7801,544$192$107$85
Aug7631,545$192$109$83
Sep6211,389$174$107$67
Oct6211,080$134$71$63
Nov433997$125$81$44
Dec3711,297$160$121$39
Printed totals7,33914,941$1,862$1,089$772

The summary forecast lists 7,341 kWh annual generation, while the monthly table prints 7,339 kWh. The summary's assumed use is 14,940 kWh, while the monthly table prints 14,941 kWh. The proposal's 49% modeled production-to-use figure depends on the placeholder and is not a bill-reduction rate or a measured result.

Why are there two different savings figures for year one?

The 12-month table prints $772 in estimated first-year savings. The separate 25-year projection starts at $529 in 2026. The two series are both shown as printed; the documents do not explain their difference well enough to present either as a reliable prediction.

Separate long-term cash-flow model exactly as printed
Model yearAnnual savingsCumulative net position
2026$529−$31,291
2027$550−$30,742
2028$572−$30,170
2029$595−$29,576
2030$618−$28,957
2031$643−$28,314
2032$669−$27,646
2033$696−$26,950
2034$723−$26,227
2035$752−$25,474
2036$782−$24,692
2037$814−$23,878
2038$846−$23,032
2039$880−$22,152
2040$915−$21,237
2041$952−$20,285
2042$990−$19,295
2043$1,030−$18,266
2044$1,071−$17,195
2045$1,114−$16,081
2046$1,158−$14,923
2047$1,204−$13,719
2048$1,253−$12,466
2049$1,303−$11,164
2050$1,355−$9,809

The quote reports $22,011 in lifetime modeled bill savings and ends its separate cash-flow model at −$9,809. The source uses a 4% annual utility cost escalation, a 6.75% financial discount rate, and assumed energy and fixed charges of $0.11/kWh and $20.34/month. No account tariff or price path was verified.

System Advisor Model 2020.02.29.r2 is identified in the file; it lists 14.5% total system losses and 3.1% inverter loss. These are design inputs, not a field test. Model charts do not prove commissioning, output, battery performance, payoff or savings.

This was a site-specific, non-binding proposal. No executed contract, customer payment, permit or utility approval, installed-equipment photo, meter record or operating outcome was verified.

Start a solar quote with 12 months of actual use

Provide the full year of bills if possible, then identify the loads you want to keep running. A quote should distinguish the preliminary roof layout, the bill model and the battery-backup design.

Ask about a Nashville solar design

Source: Anonymized The Metal Roofers residential solar estimate, pp. 1–6. Monthly and annual projections reproduced separately. No customer data, roof aerial or equipment installation claimed.