Nashville, Tennessee · Residential proposal · Modeled results

A 22.525 kW Nashville solar proposal and its separate roof estimate

This Nashville solar proposal quoted 53 modules and two EG4 batteries for $79,870. It separately estimated $8,000 for garage roofing, subject to site and decking inspection. The attached energy model projected about 92% of estimated annual electricity use, but its financial worksheet used a different and unreconciled cost basis.

Proposed PV array rating
22.525 kW DC
Combined quoted storage
28.6 kWh
Gross solar package estimate
$79,870

Which work belonged to the solar price?

The solar scope and the approximate garage roof scope appear as separate lines. The record does not present a reconciled final combined quote or establish that the roof work was ordered.

Equipment and scope from the archived quote
ItemWhat was specified
Solar array53 Jinko JKM425N-54HL4 panels rated at 425 W each; 22.525 kW DC.
Hybrid inverterOne EG4 FlexBOSS21. The quoted equipment list and design assumptions do not establish a verified final operating configuration.
Battery storageTwo EG4 PowerPro WallMount batteries at 14.3 kWh each, 28.6 kWh combined as quoted.
Included solar workRacking, electrical integration, protection equipment, basic system tests, monitoring onboarding, setup and cleanup as scoped. Final mount approach was to be confirmed on site.
Separate garage roof estimateApproximately $8,000 for the historic garage roofing scope, with existing covering removal, deck inspection, underlayment, shingle covering, flashing and ventilation work as described. Final site conditions and decking repair could change the amount. This historic line is not a current asphalt installation offer.

The gross solar quote was $79,870. The two prices are not reported here as a combined executed contract or payment. The packet is dated September 4, 2025 and states that it is a non-binding estimate.

What did the proposal model month by month?

The rounded first-year model totals 29,067 kWh of generation and 31,600 kWh of estimated use. It also estimates 12,715 kWh imported and 9,446 kWh exported, because an annual generation ratio does not describe when the property consumes electricity. The tariff or credit treatment was not verified with the utility.

Estimated generation and household use (kWh)

01,0002,0003,0004,000JanFebMarAprMayJunJulAugSepOctNovDecModeled productionEstimated household use
Both series use the exact printed monthly kWh table below; an annual ratio does not show hourly self-consumption.

Modeled monthly electricity bill (USD)

$0$100$200$300$400JanFebMarAprMayJunJulAugSepOctNovDecBefore proposed systemAfter proposed system
These are projected bills, not utility statements or a promise of bill savings.
First-year modeled figures, as printed in the proposal
MonthSolar generation (kWh)Estimated use (kWh)Imported after (kWh)Exported after (kWh)Export creditBill beforeBill afterEstimated savings
Jan1,3522,4001,247155$3$278$152$127
Feb1,8163,0001,551319$6$343$181$161
Mar2,4512,500915801$14$289$104$185
Apr2,8872,2006621,284$23$252$67$185
May3,1042,4006101,240$22$274$62$211
Jun3,4461,8002381,811$33$220$18$202
Jul3,3393,2001,0611,128$20$375$118$258
Aug3,1643,1001,0911,082$19$364$122$242
Sep2,4693,3001,474582$10$386$173$213
Oct2,2902,7001,129654$12$305$128$177
Nov1,5232,4001,184254$5$273$141$133
Dec1,2262,6001,553136$2$300$185$115
Sum of rounded months (calculated)29,06731,60012,7159,446$169$3,659$1,451$2,209

Average monthly bill comparison in the source

$0$50$100$150$200$250$300$350$400Before solarAfter solar
Bars preserve the relative height of the original source graphic. They were not individually labeled with dollar values.

Average daily generation and estimated use (kWh/day)

0255075100125150JanFebMarAprMayJunJulAugSepOctNovDecGenerationEstimated use
Generation bars use the printed daily values. Daily use is calculated from the model’s rounded monthly kWh divided by calendar days because the original daily use curve did not label its points.

How to read the model: The final row sums the source’s rounded figures; $3,659 before minus $1,451 after is $2,208 while the separately rounded savings rows total $2,209. The estimated-use baseline exceeds 500 kWh in every month although the rate label says below 500 kWh. $169 summed export credit also does not equal 9,446 kWh multiplied by the displayed $0.02/kWh ($188.92). No precise rate or utility statement was verified.

Which assumptions drive the estimates?

Technical and tariff inputs printed in the source
Model inputWhat the proposal used
Modeled roof arrangement14 modules at azimuth 156°, 13 at 245°, and 26 combined at 66°, all modeled at 26° tilt. Site placement was not approved or verified.
Performance modelSystem Advisor Model 2020.02.29.r2; total losses 12.8%, inverter loss 3.1%, optimizer loss 1.5%, shade and performance adjustments 0% as modeled.
Tariff assumptionNashville Electric Service below-500-kWh DPP model label; $0.11/kWh displayed seasonal usage, $0.02/kWh displayed export, and a $20.34 monthly fixed charge. Exact account rate is not supplied.
Financial assumptions4% annual electricity cost growth; check the worksheet’s discounting and fee assumptions against the original tariff before relying on projected savings. The sheet excludes out-of-warranty replacement costs.

The utility-savings figure printed by the model is $63,188. Its separate cost worksheet uses $61,316 and prints $1,872 as modeled net savings. The quote sheet instead lists $79,870 for solar alone and does not reconcile the $61,316 basis. Comparing the gross solar quote to the same utility savings leaves $16,682 rather than a positive return. These are separate source and arithmetic scenarios, not actual financial outcomes.

Source cumulative bill savings with export credit

$0$10,000$20,000$30,000$40,000$50,000$60,000$70,00015101520Year 20: $63,188Lower segmentUpper segment
The five stacks preserve the original bar geometry. The printed legend describes the combined amount; only the year-20 endpoint was labeled separately.

Cumulative net position in the source model

−$75k−$50k−$25k$0k$25k$50k$75k202520292034203920442044: +$1,872 in original model
This is the modeled net position using the financial worksheet’s own cost basis. It is not reconciled to the gross quote. The source bars were not individually labeled.

Upfront modeled investment and annual savings

−$75k−$50k−$25k$0k$25k$50k$75k20252029203420392044
Original annual bar heights with the initial cost below zero. No new annual amounts are inferred or presented.

What this quote does and does not establish

The historic proposal and attached model document what was offered. The available copy does not verify acceptance, a received tax credit, payment, verified installation or inspection, metered output, or actual returns. The attachment’s technical illustrations and identifying property information are not reproduced.

Ask for a site-specific solar quote