Nashville, Tennessee · Residential proposal · Modeled results
A 22.525 kW Nashville solar proposal and its separate roof estimate
This Nashville solar proposal quoted 53 modules and two EG4 batteries for $79,870. It separately estimated $8,000 for garage roofing, subject to site and decking inspection. The attached energy model projected about 92% of estimated annual electricity use, but its financial worksheet used a different and unreconciled cost basis.
- Proposed PV array rating
- 22.525 kW DC
- Combined quoted storage
- 28.6 kWh
- Gross solar package estimate
- $79,870
Which work belonged to the solar price?
The solar scope and the approximate garage roof scope appear as separate lines. The record does not present a reconciled final combined quote or establish that the roof work was ordered.
| Item | What was specified |
|---|---|
| Solar array | 53 Jinko JKM425N-54HL4 panels rated at 425 W each; 22.525 kW DC. |
| Hybrid inverter | One EG4 FlexBOSS21. The quoted equipment list and design assumptions do not establish a verified final operating configuration. |
| Battery storage | Two EG4 PowerPro WallMount batteries at 14.3 kWh each, 28.6 kWh combined as quoted. |
| Included solar work | Racking, electrical integration, protection equipment, basic system tests, monitoring onboarding, setup and cleanup as scoped. Final mount approach was to be confirmed on site. |
| Separate garage roof estimate | Approximately $8,000 for the historic garage roofing scope, with existing covering removal, deck inspection, underlayment, shingle covering, flashing and ventilation work as described. Final site conditions and decking repair could change the amount. This historic line is not a current asphalt installation offer. |
The gross solar quote was $79,870. The two prices are not reported here as a combined executed contract or payment. The packet is dated September 4, 2025 and states that it is a non-binding estimate.
What did the proposal model month by month?
The rounded first-year model totals 29,067 kWh of generation and 31,600 kWh of estimated use. It also estimates 12,715 kWh imported and 9,446 kWh exported, because an annual generation ratio does not describe when the property consumes electricity. The tariff or credit treatment was not verified with the utility.
Estimated generation and household use (kWh)
Modeled monthly electricity bill (USD)
| Month | Solar generation (kWh) | Estimated use (kWh) | Imported after (kWh) | Exported after (kWh) | Export credit | Bill before | Bill after | Estimated savings |
|---|---|---|---|---|---|---|---|---|
| Jan | 1,352 | 2,400 | 1,247 | 155 | $3 | $278 | $152 | $127 |
| Feb | 1,816 | 3,000 | 1,551 | 319 | $6 | $343 | $181 | $161 |
| Mar | 2,451 | 2,500 | 915 | 801 | $14 | $289 | $104 | $185 |
| Apr | 2,887 | 2,200 | 662 | 1,284 | $23 | $252 | $67 | $185 |
| May | 3,104 | 2,400 | 610 | 1,240 | $22 | $274 | $62 | $211 |
| Jun | 3,446 | 1,800 | 238 | 1,811 | $33 | $220 | $18 | $202 |
| Jul | 3,339 | 3,200 | 1,061 | 1,128 | $20 | $375 | $118 | $258 |
| Aug | 3,164 | 3,100 | 1,091 | 1,082 | $19 | $364 | $122 | $242 |
| Sep | 2,469 | 3,300 | 1,474 | 582 | $10 | $386 | $173 | $213 |
| Oct | 2,290 | 2,700 | 1,129 | 654 | $12 | $305 | $128 | $177 |
| Nov | 1,523 | 2,400 | 1,184 | 254 | $5 | $273 | $141 | $133 |
| Dec | 1,226 | 2,600 | 1,553 | 136 | $2 | $300 | $185 | $115 |
| Sum of rounded months (calculated) | 29,067 | 31,600 | 12,715 | 9,446 | $169 | $3,659 | $1,451 | $2,209 |
Average monthly bill comparison in the source
Average daily generation and estimated use (kWh/day)
How to read the model: The final row sums the source’s rounded figures; $3,659 before minus $1,451 after is $2,208 while the separately rounded savings rows total $2,209. The estimated-use baseline exceeds 500 kWh in every month although the rate label says below 500 kWh. $169 summed export credit also does not equal 9,446 kWh multiplied by the displayed $0.02/kWh ($188.92). No precise rate or utility statement was verified.
Which assumptions drive the estimates?
| Model input | What the proposal used |
|---|---|
| Modeled roof arrangement | 14 modules at azimuth 156°, 13 at 245°, and 26 combined at 66°, all modeled at 26° tilt. Site placement was not approved or verified. |
| Performance model | System Advisor Model 2020.02.29.r2; total losses 12.8%, inverter loss 3.1%, optimizer loss 1.5%, shade and performance adjustments 0% as modeled. |
| Tariff assumption | Nashville Electric Service below-500-kWh DPP model label; $0.11/kWh displayed seasonal usage, $0.02/kWh displayed export, and a $20.34 monthly fixed charge. Exact account rate is not supplied. |
| Financial assumptions | 4% annual electricity cost growth; check the worksheet’s discounting and fee assumptions against the original tariff before relying on projected savings. The sheet excludes out-of-warranty replacement costs. |
The utility-savings figure printed by the model is $63,188. Its separate cost worksheet uses $61,316 and prints $1,872 as modeled net savings. The quote sheet instead lists $79,870 for solar alone and does not reconcile the $61,316 basis. Comparing the gross solar quote to the same utility savings leaves $16,682 rather than a positive return. These are separate source and arithmetic scenarios, not actual financial outcomes.
Source cumulative bill savings with export credit
Cumulative net position in the source model
Upfront modeled investment and annual savings
What this quote does and does not establish
The historic proposal and attached model document what was offered. The available copy does not verify acceptance, a received tax credit, payment, verified installation or inspection, metered output, or actual returns. The attachment’s technical illustrations and identifying property information are not reproduced.