Nashville, Tennessee · Residential proposal · Modeled results

A 10.2 kW Nashville solar proposal with a Sol-Ark inverter and EG4 battery

A Nashville estimate quoted 24 rooftop-design solar modules and one EG4 battery for $40,610. The underlying model reports 84% generation relative to estimated annual use. It also mentions an existing system, so its forecast cannot be used to isolate the effect of the new equipment.

Quoted new module capacity
10.2 kW
Storage named in the scope
14.3 kWh
Gross September 2025 quote
$40,610

What was included in the Nashville estimate?

The quote specified a Sol-Ark hybrid inverter and one wall-mounted battery for backup and self-consumption. The source did not provide a verified backed-up load list or runtime. The roof model proposed east- and west-facing groups; the estimate left final mounting for a site visit.

Equipment and scope from the archived quote
ItemWhat was specified
Solar array24 Jinko Solar JKM425N-54HL4 panels at 425 W apiece; 10.2 kW DC.
Hybrid inverterOne Sol-Ark 12K-2P-N listed to support solar, battery integration and monitoring.
BatteryOne EG4 PowerPro WallMount lithium iron phosphate battery, listed at 14.3 kWh in the quote.
Mounting and electricalRails, clamps, flashings if roof-mounted, electrical integration, disconnects, monitoring setup, testing, owner walk-through and site cleanup as scoped.
Quoted priceSeptember 18, 2025 gross non-binding estimate $40,610. No verified payment or signed acceptance.

The proposal illustrated a historical assumed incentive of $12,183 and a resulting $28,427 net scenario. It does not establish a received credit or actual eligibility. The scope refers to manufacturer documents rather than granting a new product warranty.

What did the proposal model month by month?

The design summary reports an 84% generation-to-use comparison. The 12 rounded source rows sum to 12,503 kWh of generation and 14,941 kWh of use, compared with 14,940 kWh of estimated use in the narrative. The model’s recorded baseline and after-solar bill columns sum to $1,862 and $834.

Estimated generation and household use (kWh)

04008001,2001,600JanFebMarAprMayJunJulAugSepOctNovDecModeled productionEstimated household use
Both series use the exact printed monthly kWh table below; an annual ratio does not show hourly self-consumption.

Modeled monthly electricity bill (USD)

$0$50$100$150$200JanFebMarAprMayJunJulAugSepOctNovDecBefore proposed systemAfter proposed system
These are projected bills, not utility statements or a promise of bill savings.
First-year modeled figures, as printed in the proposal
MonthSolar generation (kWh)Estimated use (kWh)Imported after (kWh)Exported after (kWh)Export creditBill beforeBill afterEstimated savings
Jan5581,4759345$0$179$121$58
Feb7651,31866590$2$162$90$72
Mar1,0511,095367291$5$138$54$83
Apr1,267972253517$9$123$38$85
May1,371964161531$10$122$28$94
Jun1,5231,265330553$10$161$47$114
Jul1,4701,544500391$7$192$69$123
Aug1,3711,545548338$6$192$75$117
Sep1,0511,389566198$4$174$79$95
Oct9571,080380224$4$134$56$78
Nov62699746366$1$125$68$58
Dec4931,2978253$0$160$109$51
Sum of rounded months (calculated)12,50314,9415,9923,207$58$1,862$834$1,028

Source average monthly electricity bill graphic

$0$25$50$75$100$125$150$175Before solarAfter solar
These are the relative heights of the original two unlabeled bars, not independently measured monthly averages.

Original average daily production (kWh/day)

0102030405060JanFebMarAprMayJunJulAugSepOctNovDecProductionEstimated use
Generation bars use exact source labels. Daily estimated use is derived from the rounded monthly table and calendar days because the source use curve does not give point values.

How to read the model: The annual row sums the rounded months; it is not printed as a totals row. The proposal applies a residential below-500-kWh tariff label even though all modeled use values exceed 500 kWh. The source identifies an existing system in its model without separately breaking out the two systems’ energy. Do not treat the projected change as verified incremental output from the new system.

Which assumptions drive the estimates?

Technical and tariff inputs printed in the source
Model inputWhat the proposal used
Roof planning12 modules at 267° azimuth and 12 at 88°, all at 26° slope.
Model settingsSystem Advisor Model 2020.02.29.r2. Total losses 15.1%, inverter losses 3.5%, optimizers and shading 0%, performance adjustment 0% as modeled.
Historical billing inputsNashville Electric Service Residential Rate below-500-kWh DPP label; $0.11/kWh shown for both summer and winter. The attached rate page does not state a verified tariff or complete charge schedule.
EscalationThe estimate assumes a 4% increase in energy costs per year. No account rate change or future bills are verified.

The attached 20-year projection prints $29,463 in modeled utility savings plus export credit. It is not measured, and the source does not subdivide the projection into independent timelines with and without the existing system.

Source cumulative bill savings plus export credit

$0k$5k$10k$15k$20k$25k$30k15101520Year 20: $29,463Lower source segmentUpper source segment
The five bars preserve the original chart shape, with only the printed total labeled. The original legend combines savings and export credit without identifying the individual colors.

What this quote does and does not establish

This is a site-specific estimate and attached model. Nothing in the reviewed packet establishes a completed installation, utility approval, payments, replacement commissioning, or metered production. Customer details, private equipment layout and proprietary source images are omitted.

Ask for a site-specific solar quote

Source: Anonymized ten-page The Metal Roofers estimate and supporting forecast. Quote and scope, pp. 1–2; performance assumptions and example operation, pp. 3–4; monthly model, rate and cumulative charts, p. 5; manufacturer literature, pp. 6–10.