Murfreesboro, Tennessee · Residential proposal · Modeled results

A 10.2 kW Murfreesboro rooftop solar proposal with six tilt-mounted panels

This Murfreesboro quote proposed putting 24 Jinko modules across two roof planes, with six modules on adjustable tilt racks. It priced one Sol-Ark hybrid inverter and the installed rooftop scope at $35,700. No battery was included. The attached model reports production equal to about 95% of the estimated annual use.

Proposed DC array
10.2 kW
Modules on tilt racks
6 of 24
Historical cash estimate
$35,700

What made the Murfreesboro quote different from a standard rooftop layout?

The estimate specified adjustable mounts on a low-slope section for six of the 24 panels. The remaining 18 modules were planned on their own face. Final site conditions, not the paper design alone, would establish the actual racking and placement.

Equipment and scope from the archived quote
ItemWhat was specified
Modules and racking24 JinkoSolar JKM425N-54HL4 modules, 425 W each, totaling 10.2 kW DC. Adjustable tilt racks for six only.
Hybrid inverterOne Sol-Ark 12K-2P-N. Hybrid controls and monitoring are listed, but there was no battery in the proposed equipment scope.
Installation and approvals scopeRails, wiring and protection equipment, installation, permit coordination and utility interconnection submissions, testing and monitoring setup at turnover as quoted.
Historical cash amountJune 7, 2025 unsigned estimate for $35,700 gross. Neither fees paid nor an executed price were verified.

The source's historical illustration used a $10,710 incentive assumption and a $24,990 net scenario. No actual incentive, eligibility, payment or current price is implied. The estimate states 25-year panel product and 30-year performance terms; actual manufacturer coverage is not verified.

What did the proposal model month by month?

The estimate's 95% is an annual energy comparison, not a bill reduction. From the printed rounded months, the model totals 14,193 kWh of generation and 14,941 kWh of estimated use. It still estimates 9,236 kWh imported and 8,488 kWh exported because production and use do not necessarily happen at the same times.

Estimated generation and household use (kWh)

04008001,2001,600JanFebMarAprMayJunJulAugSepOctNovDecModeled productionEstimated household use
Both series use the exact printed monthly kWh table below; an annual ratio does not show hourly self-consumption.

Modeled monthly electricity bill (USD)

$0$50$100$150$200JanFebMarAprMayJunJulAugSepOctNovDecBefore proposed systemAfter proposed system
These are projected bills, not utility statements or a promise of bill savings.
First-year modeled figures, as printed in the proposal
MonthSolar generation (kWh)Estimated use (kWh)Imports after (kWh)Exports after (kWh)Export creditBill beforeBill afterEstimated savings
Jan7381,4751,038301$5$170$121$49
Feb9561,318869508$9$154$100$54
Mar1,2251,095659789$14$132$74$58
Apr1,383972551962$17$119$60$60
May1,419964507962$17$119$55$63
Jun1,5291,265676940$17$149$73$76
Jul1,4931,544853802$14$177$93$84
Aug1,4601,545898813$15$177$97$80
Sep1,1841,389853648$12$161$96$65
Oct1,2151,080672807$15$130$75$55
Nov850997684537$10$122$81$41
Dec7411,297976419$8$152$112$40
Sum of rounded months (calculated)14,19314,9419,2368,488$153$1,762$1,037$725

Average monthly bill comparison in the source

$0$25$50$75$100$125$150$175$200Before solarAfter solar
Bars preserve the relative height of the original source graphic. They were not individually labeled with dollar values.

Average daily generation and estimated use (kWh/day)

0102030405060JanFebMarAprMayJunJulAugSepOctNovDecGenerationEstimated use
Generation bars use the printed daily values. Daily use is calculated from the model’s rounded monthly kWh divided by calendar days because the original daily use curve did not label its points.

How to read the model: The annual row is calculated from printed rounded months; the narrative instead prints 14,940 kWh estimated annual use. No actual monthly meter data are available. The same monthly use series appears in another independent design file, so it must be regarded as a model input, not verified property bills. The estimated before/after bill comparison sums to $1,762 versus $1,037.

Which assumptions drive the estimates?

Technical and tariff inputs printed in the source
Model inputWhat the proposal used
Model layout18 modules at azimuth 188° and tilt 27°, plus six at azimuth 278° and tilt 20°.
Performance inputsSystem Advisor Model 2020.02.29.r2: 11.8% total losses, 3.5% inverter loss, 1.5% optimizer loss, 0.3% shade loss and 0% performance adjustment.
Historical tariffMiddle Tennessee Electric residential DPP label; displayed $0.08/kWh usage and $0.02/kWh TVA fuel cost adjustment. Source is not the verified current customer tariff.
Escalation4% modeled electricity cost growth per year. Actual energy prices and export payments were not supplied.

The $19,778 original cumulative utility-bill projection is a modeled result, not a payment, meter reading, accepted return, or proof that this equipment was installed.

Source cumulative bill savings with export credit

$0$5,000$10,000$15,000$20,00015101520Year 20: $19,778Lower segmentUpper segment
The five stacks preserve the original bar geometry. The printed legend describes the combined amount; only the year-20 endpoint was labeled separately.

What this quote does and does not establish

This exact property has a separate original proposal from the Nashville 10.2 kW system with storage. Equipment, city, scope and use assumptions here come from this specific unsigned estimate. No paid invoice, installation, commissioning, utility approval or metered production was verified.

Ask for a site-specific solar quote

Source: Anonymized 12-page The Metal Roofers quote and appendices. Scope and quoted amount pp. 1–2; performance and operating illustrations pp. 3–4; table and historical graphs p. 5; attached product literature pp. 6–12.