Solar case study · Lynnville, Tennessee

8.64 kW of solar with 28.6 kWh of battery storage in Lynnville

Can a solar system generate more than I use and still leave me with a utility bill?

Yes. In this Lynnville, Tennessee case, an 8.64 kW system was modeled to generate 12,048 kWh a year against 9,150 kWh of annual electricity use, or about 132%. The same model still showed power drawn from the grid in some months. Fixed charges and the rate paid for exported power affect the bill, so 132% of annual usage does not mean 132% bill savings.

Sixteen rooftop panels paired with two batteries show why an annual solar percentage only tells part of the story. The Lynnville model put yearly generation above yearly electricity use, while still showing both winter grid purchases and a remaining utility bill.

Rooftop solar capacity
8.64 kW DC
Nominal battery capacity
28.6 kWh
2025 gross system price
$45,940

Equipment · Monthly model · Cost and assumptions

What made up the Lynnville system?

Sixteen 540-watt modules total 8.64 kW DC. The roof model placed the panels on one plane at a 20-degree slope and a 196-degree azimuth, or 16 degrees west of due south. The 12 kW inverter rating describes power, while the 28.6 kWh battery rating describes nominal stored energy. Those numbers answer different questions.

Panels, inverter, batteries and roof-mounted hardware
ComponentEquipment and configuration
Solar modules16 Jinko Solar JKM540M-72HL4-V modules, at 540 W each.
Hybrid inverterOne EG4 18KPV-12LV, listed at 12 kW.
Battery storageTwo EG4 PowerPro WallMount batteries, 14.3 kWh nominal each.
Mounting detailEight black UFO-END-01-B1 end clamps; listed clamp fit is 30 to 40 mm.

When solar is strong

The system model sends solar to the home, stores available surplus in the batteries, and allows modeled exports when there is more energy than the home or batteries can take.

When solar only covers part of demand

The home can draw on more than one source. Battery state and demand timing matter, so a month with strong solar can still show imported electricity.

After sunset

There is no live solar generation in the model’s nighttime view. The home uses available battery energy or grid electricity. Actual runtime depends on the circuits, load, and how much battery energy is available.

What does 132% annual generation mean?

The model calculated 12,048 kWh of solar generation against 9,150 kWh of annual electricity use. That is 132% on an annual energy basis, rounded. It is not the share of the bill eliminated or the share of every hour covered. January still modeled 991 kWh of grid imports; May showed no grid imports and 727 kWh of exports.

Monthly electricity use and modeled solar generation04008001,2001,600JanFebMarAprMayJunJulAugSepOctNovDec
Dark teal: baseline use. Copper: modeled solar. Both series are in kWh per month.
Monthly utility bills before and with modeled solar$0$60$120$180$240JanFebMarAprMayJunJulAugSepOctNovDec
Dark teal: bill before solar. Copper: bill with modeled solar. The model retains a monthly charge even in several months with no imported electricity.
Full 12-month energy and bill model
MonthSolar generation
(kWh)
Baseline use
(kWh)
Grid import
(kWh)
Grid export
(kWh)
Export creditBill before solarBill with solarBill savings
Jan6291,6009910$0$205$141$63
Feb81890021885$2$132$59$73
Mar1,0456002404$7$101$38$63
Apr1,1764500698$13$85$38$47
May1,2024500727$13$85$38$47
Jun1,2967500508$9$116$38$78
Jul1,26490014328$6$132$38$94
Aug1,2348007393$7$121$38$83
Sep1,00180057213$4$121$40$81
Oct1,0305000499$9$90$38$52
Nov72250030213$4$90$38$52
Dec63190032735$1$132$72$60
Sum of rows12,0489,1501,6464,103$75$1,410$616$793

The dollar columns are separately rounded. Adding the 12 displayed savings figures gives $793, while subtracting the displayed bill totals gives $794.

How should you read the price and savings together?

$45,940 is the gross 2025 system price for this case. The model’s 20-year utility-bill savings endpoint was $24,059. That number models electricity-bill reductions before subtracting the purchase and replacement costs. The price and modeled savings are specific to this case.

Tariff assumptions

The model used a Duck River Electric residential rate with a $0.08/kWh base usage charge, approximately $0.02/kWh in fuel adjustments, a $0.02/kWh export credit, and a $38.06 fixed monthly charge. These were model inputs, not current rates or export terms.

Output assumptions

The physical model used a single 20-degree roof plane, 15.8% modeled total system losses, and a zero-shading input. A different roof, orientation, tree line, or solar layout can change the result.

Long-term assumptions

The utility-bill model assumed 4% annual energy cost escalation. The separate financial analysis used a 6.75% discount rate and excluded uncovered equipment replacement. Actual bills depend on utility rates and how and when the site uses electricity.

To compare a system for your own property, start with 12 months of electricity usage. Then compare the hours you use power, what the roof can fit, and which circuits you want batteries to support.

See what solar and batteries could do at your property

Talk with The Solar Roofers · Compare more solar case studies

Comparing a solar design and modeled annual productionAn array layout is placed beside a simple bar chart on a set of design papers. The chart is illustrative, not measured output.
Conceptual solar planning diagram. This is not a drawing of the property or a measurement of its output.