Lookout Mountain, Georgia · One property, two signed phases
A 22.1 kW solar and metal roof project with a later Powerwall expansion
This Lookout Mountain project combined rooftop solar, two Tesla Powerwall 3 units and two types of metal roofing in one signed agreement. The same homeowner later contracted to add another Powerwall 3 and one expansion pack. The original bundle was contracted at $139,299. The separate $24,000 battery expansion is recorded as paid in full.
- Original DC solar capacity in the signed agreement
- 22.1 kW
- Original signed storage: two Tesla Powerwall 3 units
- 27.0 kWh
- Separate battery expansion verified paid
- $24,000
What was included in the original roof, solar and battery agreement?
The April 2025 agreement put the solar array on the rear standing seam roof. Selected front-facing and rear sections below the windows, plus the eyebrow roof areas, were scoped in ProVia Slate metal shingles in Coal Stone. The roof attachment, underlayment, flashing and trim could be coordinated across those systems. The standing seam scope specified on-site roll-formed Ultra-Snap panels with concealed clips and dark finish options; the final finish is not confirmed in the documents used here.
The signed solar schedule specified 52 Jinko JKM425N-54HL4 modules at 425 watts each and two Tesla Powerwall 3 batteries at 13.5 kWh each. It listed roof racking and mounting hardware, battery mounting components, wiring, conduit, protection and interconnection materials. The signed scope does not establish an exact battery backup runtime or what the household could run during an outage.
| Scope | Signed price | What was covered |
|---|---|---|
| Solar and battery system | $92,810 | 52 panels, two Powerwall 3 units, racking, mounting and interconnection materials. |
| Standing seam roof | $20,400 | Rear solar roof area, existing roof removal, deck preparation, underlayment, flashing, trim and ridge ventilation. |
| Metal shingle roof | $26,089 | ProVia Slate metal shingles on selected roof sections, including detail work and underlayment as specified. |
| Total signed bundle | $139,299 | Combined roof and solar scope. It is not the solar-only price and is not shown as an amount paid. |
The contract scheduled 30% at deposit ($41,789.70), 30% at equipment procurement ($41,789.70), 35% at installation completion ($48,754.65) and 5% at commissioning ($6,964.95). The original job entry is marked Closed, but the record reviewed contained no payment invoices for this phase. The bundle’s scope sheets tied pricing to the combined work and excluded new fascia and soffit. The signed equipment schedule references 12 years for the module product warranty, 30 years for module performance, and 10 years for the Powerwall units. Those are historical contract references, not verification of current product coverage or warranty registration.
What changed in the later Powerwall expansion?
The September 30, 2025 scope attachment, signed with its agreement October 1, explicitly links to the original project. It lists one additional Tesla Powerwall 3 and one expansion pack for the existing configuration. It does not specify the expansion-pack model or resulting usable capacity, so the final storage capacity is not asserted here. This was a separate storage scope. No additional solar panels are listed.
| Invoice | Amount paid | Recorded status |
|---|---|---|
| Deposit | $14,400 | Paid |
| Final payment | $9,600 | Paid |
| Total for this phase | $24,000 | Paid in full; remaining invoice balance $0. |
Why these two prices are separate: The $139,299 is a signed roof-and-solar contract total. The $24,000 is a separate paid expansion. The records do not establish the combined amount paid across both phases.
What did the earlier design model for the original 52-panel system?
Earlier unsigned proposal only. This OpenSolar design expired April 9, 2025, before the original agreement was signed. It lists the same property and original equipment: 52 of the same 425 W Jinko modules and two Powerwall 3 units. Its stand-alone cash quote was $96,250, not the later $92,810 signed solar line, the $139,299 signed roof-and-solar bundle, or the paid battery add-on.
Before the later expansion, the model estimated 29,192 kWh annual generation compared with 38,558 kWh estimated annual use. It reported 76% consumption offset as a rounded generation-to-use estimate. That is not the share of use served at every hour or a prediction of the change in the utility bill.
Average daily energy by month (kWh/day)
Monthly production and estimated use (kWh)
Modeled utility bills before and after solar
Average monthly bill: before and after solar
| Month | Solar generation (kWh) | Use before (kWh) | Net use after (kWh) | Bill before | Bill after | Cumulative energy credit | Estimated savings |
|---|---|---|---|---|---|---|---|
| Jan | 1,697 | 3,544 | 1,892 | $369 | $201 | $0 | $167 |
| Feb | 1,896 | 2,774 | 923 | $291 | $103 | $0 | $188 |
| Mar | 2,391 | 2,622 | 293 | $275 | $39 | $0 | $236 |
| Apr | 2,898 | 2,380 | (440) | $251 | $9 | $45 | $241 |
| May | 2,956 | 2,872 | (15) | $300 | $9 | $46 | $291 |
| Jun | 2,957 | 3,558 | 675 | $370 | $32 | $0 | $338 |
| Jul | 2,940 | 4,277 | 1,407 | $443 | $152 | $0 | $291 |
| Aug | 2,994 | 4,163 | 1,245 | $431 | $136 | $0 | $296 |
| Sep | 2,538 | 3,649 | 1,175 | $379 | $128 | $0 | $251 |
| Oct | 2,430 | 2,821 | 461 | $295 | $56 | $0 | $239 |
| Nov | 1,971 | 2,611 | 698 | $274 | $80 | $0 | $194 |
| Dec | 1,524 | 3,286 | 1,810 | $343 | $193 | $0 | $150 |
How to read the original numbers: Monthly production adds to 29,192 kWh, while the twelve use values add to 38,557 kWh, 1 kWh below the proposal’s rounded annual summary. Negative net use in April and May is a modeled monthly surplus, not proof the house was off-grid. The energy-credit column is cumulative, not a set of amounts to add. Rounded bills and savings need not subtract exactly.
Assumptions behind the early design
It modeled 52 modules at 24° tilt and 166° azimuth; total system losses 15.4%, inverter losses 3.0%, shading loss 0.2%, optimizer loss and performance adjustment 0%. It used the System Advisor Model version identified in the proposal. The cited tariff assumptions were $0.10/kWh, a $9.36 monthly fixed charge and a 4% annual escalation. These are the early model values for this property, not current tariffs.
For the source’s long-term financial comparison, it modeled $82,988 in lifetime utility-bill savings and $15,613 in net savings after a modeled $67,375 system cost. That $67,375 depended on a historical incentive assumption the file does not verify. The model used a 6.75% discount rate and did not include out-of-warranty replacement costs. The unsigned proposal excluded a retailer smart meter. Its module product warranty label also differed from the later signed equipment schedule, so the earlier 15-year label does not replace the signed terms.
Cumulative utility-bill savings projection
Cumulative net savings model
Annual savings model and initial investment
What other solar and roof options were quoted for this property?
Other March and April records for the same property show different rooftop, battery and roof scopes. These revisions and alternatives do not add to the $139,299 signed agreement or the $24,000 paid expansion. Prices below are original quoted totals before modeled incentives.
| Quote date | Configuration | Gross quote | What changed |
|---|---|---|---|
| Mar 11 | 35 400 W modules, Enphase IQ8+ and two FranklinWH aPower 2 batteries | $68,973 | Equipment count yields 14.00 kW DC; the narrative says 15.8 kW. Two 15 kWh batteries total 30 kWh. The offer also lists an aGate X, an IQ Combiner and IronRidge mounting. |
| Mar 12 | 52 425 W Jinko modules, two Powerwall 3 units and one expansion battery | $105,700 | 22.10 kW DC and 40.5 kWh across the 27.0 kWh pair and the 13.5 kWh expansion. The chart below models this option, not the eventual signed configuration. |
| Mar 13 | 52 425 W Jinko modules and two Powerwall 3 units | $93,810 | 22.10 kW DC and 27.0 kWh storage. The narrative separately lists $92,810, $1,000 below the printed total; the document does not reconcile them. |
| Apr 10 | Same two-battery solar scope plus standing seam roofing | $114,210 | Printed solar line $93,810 plus roofing $20,400. The narrative separately lists $92,810 for solar. |
| Apr 11 | Same two-battery solar scope plus standing seam roofing | $113,210 | Printed solar line $92,810 plus roofing $20,400. The signed scope added a separate $26,089 metal shingle line not included in this estimate. |
The FranklinWH offer provides equipment and pricing but does not contain a site-specific monthly production or bill model. The standalone three-page 76% modeling export repeats the earlier proposal's chart values shown above; it is not another quote. The three later two-battery price revisions do not supply their own new monthly models.
March 12 Tesla alternative: the complete first-year model
The 40.5 kWh option modeled 31,492 kWh of annual generation against 38,558 kWh of annual use, or 82% modeled consumption offset. That is annual modeled generation relative to demand, not the share of loads backed up overnight or a claim that there would be no utility purchases. The separate 76% model and the signed project are documented above.
| Month | Generation (kWh) | Use before (kWh) | Grid import (kWh) | Grid export (kWh) | Export credit | Bill before | Bill after | Cumulative credit | Estimated savings |
|---|---|---|---|---|---|---|---|---|---|
| Jan | 1,916 | 3,544 | 1,923 | 223 | $19 | $500 | $259 | $0 | $241 |
| Feb | 1,973 | 2,774 | 1,203 | 332 | $28 | $395 | $151 | $0 | $243 |
| Mar | 2,576 | 2,622 | 779 | 629 | $53 | $374 | $68 | $0 | $306 |
| Apr | 3,064 | 2,380 | 330 | 913 | $77 | $341 | $14 | $17 | $327 |
| May | 3,140 | 2,872 | 574 | 731 | $62 | $409 | $14 | $0 | $395 |
| Jun | 3,268 | 3,558 | 973 | 571 | $48 | $715 | $127 | $0 | $588 |
| Jul | 3,207 | 4,277 | 1,512 | 332 | $28 | $866 | $258 | $0 | $608 |
| Aug | 3,149 | 4,163 | 1,488 | 364 | $31 | $842 | $250 | $0 | $592 |
| Sep | 2,678 | 3,649 | 1,459 | 397 | $34 | $725 | $239 | $0 | $487 |
| Oct | 2,548 | 2,821 | 951 | 581 | $49 | $401 | $96 | $0 | $305 |
| Nov | 2,021 | 2,611 | 1,010 | 338 | $29 | $372 | $124 | $0 | $248 |
| Dec | 1,953 | 3,286 | 1,643 | 228 | $19 | $465 | $220 | $0 | $244 |
The underlying assumptions include 166° azimuth, a 24° slope, 15.5% modeled system loss, 4% annual utility rate escalation, tiered summer rates of $0.15 to $0.21/kWh, a $0.14/kWh winter rate, a $0.08/kWh export credit and a $14.56 monthly fixed charge. The proposal selected this historic tariff by location; these are not current rates. Rounded monthly rows differ from reported annual generation and use by 1 kWh each.
The document's 20-year charts modeled $114,194 in lifetime bill savings and $40,204 in net savings after a $73,990 modeled net cost, with a 14-year modeled payback and a 6.75% discount-rate assumption. That net cost applied a historical incentive assumption to the $105,700 gross quote; neither eligibility nor receipt was verified. Replacement costs for equipment outside warranty were not included. These values are not measured savings or a price for the signed work.
What we can verify about this project
| Question | Answer supported by the file |
|---|---|
| One property or two? | One property. The later expansion scope references the original job. The two agreements cover distinct phases. |
| What was contracted? | A 22.1 kW rooftop system, 27.0 kWh of initial battery storage and two metal roof systems under the April agreement, then a Powerwall and expansion pack under the October agreement. |
| What was paid? | The $24,000 expansion is independently marked paid in full. Payment on the $139,299 original contract was not independently verified. |
| Are the model charts operating results? | No. They come from the separate unsigned proposal for the original equipment. The records reviewed do not establish metered production, measured savings, utility permission to operate, or post-expansion modeled offset. No project photos or customer-identifying roof plans are presented. |
Price a new roof, solar production and outage backup as separate decisions, even if one team coordinates all three. A design can compare estimated solar generation to usage; battery sizing also depends on which loads need backup and how long they need it.
Ask for a roof, solar and storage assessmentSources: Anonymized April and October 2025 signed The Metal Roofers agreements, paid expansion invoices, company job status, and the separate site-specific OpenSolar proposal that expired April 9, 2025. The historic model figures are not actual results or a current quote.