Historical proposal comparison | One property

Solar roof, roof-mounted panels or a separate ground array?

One job file compared three ways to combine solar and roofing. The designs carried very different prices because they did not buy the same roof, mounting system or battery package. No accepted choice, payments, utility approval or installation were verified.

Back to the solar proposal library

Three options, with pricing as quoted

OptionEnergy equipmentSolar and roof pricing
Integrated Tesla Solar RoofSolar roof tiles, a Tesla inverter in the 11.5 kW class, two main Powerwall 3 units, one expansion, and a Tesla Gateway.$434,591.33 total on the source quote. No comparable 12-month forecast was found in that proposal.
Roof-mounted panels and standing seam roof45 Jinko 425 W modules, 19.125 kW DC by module count, one Powerwall 3 and three expansions, 54 kWh as quoted.$95,175 solar and storage + $84,450 roof = $179,625.00.
Ground-mounted solar and standing seam roof36 Jinko 540 W modules, 19.44 kW DC by module count, 36 Enphase IQ8HCs, three FranklinWH aPower 2 batteries, 45 kWh by listed nameplates. Trenching in scope.$109,320 solar and storage + $84,450 roof = $193,770.00.

The ground-mount scope describes 30 degrees of tilt; the corresponding model uses 26 degrees. The table records that forecast without treating it as proof of the configuration that would have been installed.

Roof-mounted panels: all 12 modeled months

Projected solar generation by month. Annual use is not a utility bill history.
Jan1,204 kWh
Feb1,591 kWh
Mar2,121 kWh
Apr2,458 kWh
May2,624 kWh
Jun2,939 kWh
Jul2,838 kWh
Aug2,711 kWh
Sep2,162 kWh
Oct2,020 kWh
Nov1,367 kWh
Dec1,107 kWh
MonthGeneration (kWh)Assumed use (kWh)Import (kWh)Export (kWh)Credit ($)Bill before ($)Bill after ($)Savings ($)
Jan1,2041,40032821016254108
Feb1,5911,20016314614222121
Mar2,1211,20008321514222121
Apr2,4581,10001,2822313222110
May2,6241,65008731618822166
Jun2,9391,80001,0261820322181
Jul2,8382,30099505925323230
Aug2,7112,600206161328340243
Sep2,1622,50050036127371202
Oct2,0201,800149262520332171
Nov1,3671,300172132215237116
Dec1,1071,50048435117270103

The scope forecasts roughly 25,142 kWh per year. The monthly figures are the individual values shown in the original model. Independently rounded dollar columns may not subtract to the printed savings.

Ground-mounted panels: all 12 modeled months

Projected solar generation by month. Annual use is not a utility bill history.
Jan1,559 kWh
Feb1,895 kWh
Mar2,368 kWh
Apr2,605 kWh
May2,700 kWh
Jun2,914 kWh
Jul2,860 kWh
Aug2,854 kWh
Sep2,359 kWh
Oct2,468 kWh
Nov1,803 kWh
Dec1,599 kWh
MonthGeneration (kWh)Assumed use (kWh)Import (kWh)Export (kWh)Credit ($)Bill before ($)Bill after ($)Savings ($)
Jan1,5591,400224279516239123
Feb1,8951,200136261114222121
Mar2,3681,20001,0902014222121
Apr2,6051,10001,4382613222110
May2,7001,65009601718822166
Jun2,9141,80091,0231820322181
Jul2,8602,3001235651025324229
Aug2,8542,600263388728341242
Sep2,3592,500523273527369204
Oct2,4681,8001176841220322181
Nov1,8031,3001565551015227125
Dec1,5991,500411462817255118

The two panel models use the same monthly consumption inputs. A forecast does not prove production, tariff eligibility, savings or battery runtime.

Compare the roof and solar scopes separately

Before choosing, compare roof coverage, mounting or trenching, the backup equipment, and whose work is included. The three historical proposals in the same anonymized job record are the source for these figures. The printed after-incentive examples are not current pricing and are not included here.

Request a site-specific solar assessment