Huntsville, Alabama · Residential proposal · Modeled results
An 11.88 kW residential solar proposal in Huntsville
Can a home produce more electricity than it uses over a year and still receive a utility bill? This Huntsville residential proposal modeled exactly that. For $35,640, it quoted 27 Seraphim panels and a Sol-Ark hybrid inverter, with no battery in scope. The annual model compares 16,844 kWh of generation with 15,500 kWh of estimated use.
- Proposed DC solar array
- 11.88 kW
- Historical solar-only cash quote
- $35,640
- Annual production compared to estimated use
- 109% modeled
What was in this solar-only quote?
This is a residential property proposal, separate from any commercial solar work. The planned array used two roof orientations. The proposal specifies a hybrid inverter but does not price or include battery storage, so it does not document a battery-backed system.
| Item | What was specified |
|---|---|
| Solar array | 27 Seraphim SRP-440-BMA-BG modules at 440 W each, totaling 11.880 kW DC. |
| Hybrid inverter | One Sol-Ark Limitless 12K-2P-LL. |
| Mounting, integration and installation | Mounting hardware, balance-of-system materials, installation and commissioning as described in the proposal. |
| Battery | No storage capacity was quoted. |
| Archived cash price | $35,640; proposal listed validity through September 24, 2026. This is not a current offer. |
The equipment schedule lists included packages, not prices for individual products. The file includes proposed terms, not an independently verified acceptance or payment.
What did the proposal model month by month?
The model prints $2,057 before solar and $1,317 after solar in the first year, a reduction of about 36%, even with 109% annual production relative to use. The model gives no credit for exports. Estimated first-year savings of $740 are bill savings in this proposal, not operating results.
Estimated generation and household use (kWh)
Modeled monthly electricity bill (USD)
| Month | Solar generation (kWh) | Estimated use (kWh) | Bill before | Bill after | Estimated savings |
|---|---|---|---|---|---|
| Jan | 1,094 | 1,475 | $193 | $137 | $56 |
| Feb | 1,054 | 1,120 | $151 | $104 | $47 |
| Mar | 1,424 | 1,057 | $143 | $91 | $52 |
| Apr | 1,619 | 953 | $131 | $79 | $52 |
| May | 1,633 | 1,143 | $153 | $90 | $63 |
| Jun | 1,687 | 1,417 | $186 | $107 | $79 |
| Jul | 1,738 | 1,681 | $219 | $128 | $91 |
| Aug | 1,696 | 1,655 | $216 | $130 | $86 |
| Sep | 1,377 | 1,458 | $191 | $123 | $68 |
| Oct | 1,400 | 1,120 | $151 | $100 | $51 |
| Nov | 1,084 | 1,065 | $144 | $100 | $44 |
| Dec | 1,036 | 1,356 | $179 | $128 | $51 |
| Source annual totals | 16,844 | 15,500 | $2,057 | $1,317 | $740 |
How to read the model: The published annual generation total is 16,844 kWh. The individually rounded source months add to 16,842 kWh. Both are shown as printed. This revision does not tabulate monthly imports or exports, and no new values for them have been inferred.
Which assumptions drive the estimates?
| Model input | What the proposal used |
|---|---|
| Roof placement | 12 modules at 138° azimuth and 26° tilt; 15 at 198° azimuth and 26° tilt. |
| Performance inputs | System Advisor Model 2020.02.29.r2. Total system loss 15.7%; inverter loss 4.0%; optimizer, shading and performance adjustment 0% as modeled. |
| Model tariff, not a current rate | Huntsville Utilities residential rate was assumed rather than verified against an account. $0.08/kWh through 1,400 kWh, $0.09 above that, and a $0.04/kWh fuel cost adjustment were shown. No export credit was assumed. |
| Finances | 4% assumed electricity cost increase per year and a 6.75% financial discount rate. Replacement costs outside warranty were not included. |
Projected lifetime utility-bill savings were $21,797, or $13,843 less than the quoted price. That comparison uses the archive model. It is not proof of realized savings, final expenditure, or tax credit received.
Cumulative modeled utility-bill savings
What this quote does and does not establish
The proposal verifies that a real site was scoped for this system. It does not verify an installation date, final payment, completed commissioning, utility approval, or actual production. No property-identifying plans, aerial image, or customer information are included.
Ask for a site-specific solar quoteSource: Anonymized seven-page The Metal Roofers residential proposal. Equipment, pp. 1–2; performance model, p. 3; monthly table and assumed rate, p. 4; original quotation and cumulative chart, p. 5; terms and acceptance area, pp. 6–7. No executed signature was verified.