Green Hill, Tennessee · Residential proposal · Modeled results

An 8.1 kW solar and FranklinWH battery proposal in Green Hill

This Green Hill design priced 18 rooftop panels and 13.6 kWh of FranklinWH battery storage at $33,820. The attached model estimated 11,255 kWh of solar generation against 19,500 kWh of annual household use. The design shows why a projected generation ratio and a projected bill change are not the same number.

Proposed solar array size
8.1 kW
Quoted FranklinWH battery storage
13.6 kWh
Historical cash quote
$33,820

What did the Green Hill proposal include?

The quote specified a single roof orientation and one battery. It was a site-specific cash proposal, not a blanket price for FranklinWH storage or a promise that any particular loads would be covered during an outage.

Equipment and scope from the archived quote
ItemWhat was specified
Array18 Seraphim SEG-450-BMA-HV modules at 450 W each, totaling 8.100 kW DC.
InverterOne FranklinWH aPower S 11.5 kW inverter, as identified in the quote.
BatteryOne FranklinWH AC battery energy storage unit, 13.6 kWh as quoted.
Cash price and deposit$33,820. The file prints $0 deposit, not a receipt or an agreed installment schedule.
ExclusionRetailer smart meter installation was excluded; if requested, it would be extra.

The proposal listed validity through September 9, 2026. Its product-copy warranty terms listed 15 years for panel product coverage, 25 years for panel performance, and 15 years for inverter product coverage. No completed registration, separate battery warranty term, or actual live offer was verified.

What did the proposal model month by month?

The archive reports 58% annual generation relative to use. Adding the rounded printed first-year bill entries gives $2,354 before and $1,304 after solar and storage, or $1,050 in modeled bill savings. That model still includes purchases of electricity from the grid. Neither these values nor the percent offset are utility records.

Estimated generation and household use (kWh)

05001,0001,5002,0002,500JanFebMarAprMayJunJulAugSepOctNovDecModeled productionEstimated household use
Both series use the exact printed monthly kWh table below; an annual ratio does not show hourly self-consumption.

Modeled monthly electricity bill (USD)

$0$50$100$150$200$250JanFebMarAprMayJunJulAugSepOctNovDecBefore proposed systemAfter proposed system
These are projected bills, not utility statements or a promise of bill savings.
First-year modeled figures, as printed in the proposal
MonthSolar generation (kWh)Estimated use (kWh)Imported after (kWh)Exported after (kWh)Export creditBill beforeBill afterEstimated savings
Jan5911,9251,35813$0$227$166$61
Feb7661,7201,04778$1$205$131$74
Mar9771,430675202$4$174$89$85
Apr1,0971,268500305$5$154$68$86
May1,1161,258423255$5$153$60$93
Jun1,2061,651649177$3$203$89$114
Jul1,1742,01595185$2$244$124$120
Aug1,1512,01696977$1$244$126$118
Sep9381,81397074$1$221$126$95
Oct9671,410651183$3$169$86$83
Nov6791,30172988$2$158$96$62
Dec5941,6931,14732$1$202$143$59
Sum of rounded months (calculated)11,25619,50010,0691,569$28$2,354$1,304$1,050

Average daily energy by month (kWh/day)

020406080JanFebMarAprMayJunJulAugSepOctNovDecGenerationEstimated use
Daily generation values are printed in the original. Daily estimated use is calculated from the printed monthly use and calendar days because the source's daily use curve has no point labels.

Average monthly bill (source graphic)

$0$50$100$150$200$250Before solarAfter solar
The source did not print labels on these two bars; relative heights are preserved without assigning additional amounts.

How to read the model: The annual row sums 12 printed rounded values; the model itself does not print a totals row. Monthly production adds to 11,256 kWh, 1 kWh higher than the design summary. The tariff label in the file specifies a below-500-kWh residential class even though all modeled monthly use values exceed 500 kWh. The $28 summed export credit also does not equal 1,569 kWh times the displayed $0.02/kWh ($31.38); rate precision or adjustments were not documented. Recheck the actual tariff and credit before relying on the forecast.

Which assumptions drive the estimates?

Technical and tariff inputs printed in the source
Model inputWhat the proposal used
Roof orientation18 modules at 184° azimuth and 20° tilt.
Production modelSystem Advisor Model 2020.02.29.r2; total system losses 16.3%, inverter losses 4.0%; optimizer, shading and performance adjustments 0% as modeled.
Model tariff, not a verified account rateNashville Electric Service Residential Rate (<500 kWh) DPP assumption; $0.11/kWh applicable to printed seasonal lines, displayed $0.02/kWh export and $20.34 fixed per month.
Financial model4% annual utility cost increase and 6.75% discount rate; out-of-warranty equipment replacement costs excluded.

The financial summary models $27,567 in cumulative utility-bill savings against the $33,820 cash quote. That leaves a modeled $6,253 premium, not a realized return. The source charts show modeled year-by-year shapes but do not label the individual dollar values. They are reproduced without inventing those values.

Cumulative utility-bill savings

$0k$5k$10k$15k$20k$25k$30k15101520Year 20: $27,567Export creditUsage savings
The five stacked bars preserve the source geometry; the source prints only the total at year 20. The model is not a utility statement.

Modeled cumulative net position

−$40k−$30k−$20k−$10k$0k$10k$20k$30k$40k20262030203520402045 Final modeled gap: $6,253
Net position remains below zero in the printed model. Intermediate dollar values are not inferred; the $6,253 ending premium comes from the source's separate summary.

Upfront modeled cost and later annual savings

−$40k−$30k−$20k−$10k$0k$10k$20k$30k$40k20262030203520402045
Bar heights follow the source geometry, with the first negative bar representing the initial cost and later bars representing estimated annual savings. No individual dollar values were printed.

What this quote does and does not establish

The original proposal shows the quoted equipment, pricing and model, with customer-identifying site material removed. It does not establish payment, installation, utility permission to operate, outage runtime, confirmed tariffs or measured production.

Ask for a site-specific solar quote