Gadsden, Alabama · Residential proposal · Modeled results
An 8.1 kW solar proposal that modeled more energy than annual use
This Gadsden home proposal quoted 18 solar panels and one hybrid inverter for $24,300, with no battery included. The model showed 9,858 kWh of annual generation against 8,655 kWh of estimated use. It is an example of why an annual energy ratio and a utility-bill projection should be reviewed separately.
- Proposed DC module capacity
- 8.1 kW
- Archived cash quote
- $24,300
- Generation compared with estimated annual use
- 114% modeled
What hardware and labor were included?
The proposal scoped a rooftop array with one hybrid inverter. The system was battery-ready under the equipment description, but there was no battery in the quoted scope and no claim of outage runtime.
| Item | What was specified |
|---|---|
| Solar panels | 18 Seraphim SEG-450-BMA-HV modules at 450 W; 8.100 kW DC. |
| Hybrid inverter | One Sol-Ark Limitless 12K-2P-LL, listed at 12 kW continuous AC output. |
| Labor and mounting | Mounting hardware, electrical integration, installation labor, testing and commissioning as quoted. |
| Quoted total | $24,300 cash; listed validity through October 11, 2026. No current offer is implied. |
| Exclusions | No battery. Permit and inspection fees, where charged, were separate unless otherwise noted. |
The costs in this record are quote terms, not payments or an executed contract. Prices were not broken down by individual hardware item.
What did the proposal model month by month?
The source estimates yearly generation at approximately 114% of use. It also prints a first-year before-solar bill of $1,577, after-solar bill of $287 and savings of $1,290. Those estimates should not be relied on without a reconciliation of the export-credit column and a confirmed utility rate.
Estimated generation and household use (kWh)
Modeled monthly electricity bill (USD)
| Month | Solar generation (kWh) | Use before (kWh) | Net use after (kWh) | Bill before | Bill after | ECR credit in source | Estimated savings |
|---|---|---|---|---|---|---|---|
| Jan | 548 | 781 | 233 | $141 | $53 | $0 | $88 |
| Feb | 566 | 925 | 359 | $163 | $74 | $0 | $89 |
| Mar | 765 | 405 | (360) | $81 | $16 | $58 | $65 |
| Apr | 947 | 505 | (442) | $97 | $16 | $129 | $81 |
| May | 1,289 | 413 | (876) | $82 | $16 | $269 | $66 |
| Jun | 1,025 | 334 | (691) | $70 | $16 | $380 | $54 |
| Jul | 1,124 | 475 | (649) | $92 | $16 | $484 | $76 |
| Aug | 907 | 1,239 | 332 | $216 | $16 | $431 | $200 |
| Sep | 812 | 1,044 | 232 | $184 | $16 | $394 | $168 |
| Oct | 786 | 1,083 | 297 | $186 | $16 | $346 | $170 |
| Nov | 551 | 680 | 129 | $125 | $16 | $325 | $109 |
| Dec | 538 | 771 | 233 | $140 | $16 | $0 | $124 |
| Source annual totals | 9,858 | 8,655 | Not stated | $1,577 | $287 | Not stated | $1,290 |
How to read the model: The source shows a $484 July ECR credit. At the printed $0.03/kWh export rate, crediting even the entire year’s 9,858 kWh of modeled generation would yield about $296. The file does not document an opening balance or another way to reconcile that figure. The credit figures and resulting savings are retained as printed, not validated. An annual surplus also does not establish that exports occurred in every month.
Which assumptions drive the estimates?
| Model input | What the proposal used |
|---|---|
| Panel orientation | 18 modules modeled at 108° azimuth and 20° tilt. |
| Performance model | System Advisor Model 2020.02.29.r2. Total losses 21.0%; inverter losses 4.2%; optimizer losses, shading losses and performance adjustment 0% in the source. |
| Model tariff | Alabama Power Family Dwelling assumption, not verified against a customer account. Summer tiers $0.13/$0.14 per kWh; winter tiers $0.13/$0.12 per kWh. Printed ECR export amount $0.03/kWh, fixed charges $14.50 plus $1.50 per month. |
| Financial assumptions | 4% annual electricity-cost growth, 6.75% financial discount rate and no out-of-warranty equipment replacement costs included. |
The original projection prints $38,094 in lifetime utility-bill savings, $13,794 above the quote, and about 15 years to payback. Those are the unsigned proposal’s outputs, not validated returns. In particular, the export-credit mismatch should be resolved before using the payback or the resulting bill figures.
Cumulative modeled utility-bill savings
What this quote does and does not establish
The design is site-specific. The available proposal supports the quoted equipment, proposed price and the assumptions shown. It does not verify an installed system, payment, tariff enrollment, monitoring, or metered production. Property drawings and identifying details are not shown.
Ask for a site-specific solar quoteSource: Anonymized seven-page The Metal Roofers solar proposal. Equipment, pp. 1–2; performance and finances, p. 3; original 12-month model and tariff assumptions, p. 4; quotation and cumulative curve, p. 5; disclosures and quote acceptance, pp. 6–7.