Cedar Hill, Tennessee · One property, two independent designs

Solar and storage options for a Cedar Hill main house and pool house

A Cedar Hill proposal separately scoped a 21.6 kW ground mount for the main house and a 6.48 kW stand-alone roof array for the pool house. It quoted two different main-house equipment selections: $85,610 with EG4 or $93,410 with Enphase and FranklinWH. The separate pool-house design was $32,690.

Main-house ground mount, 40 panels
21.6 kW DC
Pool-house roof, 12 panels
6.48 kW DC
Archived data, not operating measurements
Two 12-month models

What did each structure’s quote include?

Gross archived prices, before any assumed incentive
ScopeEquipment and conditionsArchived quote
Main house: EG440 Jinko JKM540M-72HL4-V modules at 540 W. EG4 18KPV-12LV and FlexBOSS21 inverters, one 14.3 kWh PowerPro WallMount battery, and ground-mount and electrical work as scoped. Additional batteries were quoted at $12,000 each installed.$85,610
Main house: Enphase + FranklinWHSame 40-module nameplate capacity with 40 Enphase IQ-series microinverters and one FranklinWH aPower 2 battery at 15 kWh. Additional 15 kWh batteries were quoted at $13,500 each installed.$93,410
Stand-alone pool house12 of the same 540 W modules on the new roof, one EG4 6000EX-48HU inverter rated at 6 kW, and one 14.3 kWh EG4 PowerPro WallMount. Additional battery units were estimated at $12,000 each installed.$32,690

The main-house scope listed a ground mount roughly 50 feet from the residence and an approximately 50-foot trenching allowance. Connection to the main electrical panel was scoped; interior wiring, fixtures, and upgrades beyond that connection were excluded unless separately quoted. Technical model projections for the main-house options were presented together, not as two independently validated configurations.

The pool-house quote contemplated connection only to its dedicated panel, with equipment and wiring within the quoted boundary. The metal-roof proposal was still pending plans; interior wiring, fixtures and upgrades were excluded. The load model assumed the pool pump ran continuously and included essential lighting. The source does not establish actual loads or battery runtime.

What did the main-house model project?

The model’s main-house summary projected 27,695 kWh annually against an estimated 47,240 kWh of use, about 59%. The 40 panels were modeled at 180° azimuth and 28° tilt. The calculation uses 12.6% total system losses, 3.1% inverter loss, 1.5% optimizer loss, 3.6% shade loss, and 0% performance adjustment.

Modeled monthly production and use (kWh)

02,0004,0006,0008,000JanFebMarAprMayJunJulAugSepOctNovDecProductionEstimated use
Both series use the source’s exact printed monthly figures.

Modeled bills by month (USD)

$0$150$300$450$600$750JanFebMarAprMayJunJulAugSepOctNovDecBefore solarAfter solar
Model amounts from the source table, not measured bills.

Average daily energy (kWh/day)

050100150200250JanFebMarAprMayJunJulAugSepOctNovDecProduction per dayEstimated use per day
Daily generation follows the printed source chart. Each daily use value divides the printed monthly use by the calendar days in that month.

Before and after electricity-bill graphic

$0$150$300$450$600$750Before solarAfter solar
The source's two average-bill bars were not individually labeled. This drawing preserves their relative original heights.

Source cumulative utility-bill savings

$0$10,000$20,000$30,000$40,000$50,000$60,00015101520Year 20: $54,764Years in source model
The five bars preserve the source geometry. Only the 20-year amount was labeled in the source. This is a forecast, not actual savings.
Main house: every printed first-year model value
MonthSolar generation (kWh)Estimated use (kWh)Bill beforeBill afterEstimated savings
Jan1,1506,680$728$618$110
Feb1,5263,480$395$274$121
Mar2,3063,120$357$217$140
Apr2,6183,040$349$195$154
May2,6823,560$403$218$185
Jun2,5843,960$445$249$196
Jul3,2244,400$491$266$225
Aug2,7794,400$491$280$211
Sep2,4643,800$428$259$169
Oct2,9013,000$345$199$146
Nov1,9062,600$303$197$107
Dec1,5555,200$574$438$136
Sum of rounded source months27,69547,240$5,309$3,410$1,900

Monthly kWh sums match the annual model. Modeled bills sum to $5,309 before and $3,410 after; the rounded savings column totals $1,900.

What did the stand-alone pool-house model project?

The estimate projected 7,494 kWh of generation and 7,000 kWh of estimated annual use. The source rounds this to a 107% generation-to-use comparison, not proof that the proposal could meet every load hour without grid support. The 12 roof modules were modeled at 101° azimuth and 18° tilt. It used total loss 13.6%, inverter loss 4.0%, optimizer loss 1.5%, shading 3.9%, and performance adjustment 0%.

Modeled monthly production and use (kWh)

03006009001,200JanFebMarAprMayJunJulAugSepOctNovDecProductionEstimated use
Both series use the source’s exact printed monthly figures.

Modeled bills by month (USD)

$0$25$50$75$100$125JanFebMarAprMayJunJulAugSepOctNovDecBefore solarAfter solar
Model amounts from the source table, not measured bills.

Average daily energy (kWh/day)

010203040JanFebMarAprMayJunJulAugSepOctNovDecProduction per dayEstimated use per day
Daily generation follows the printed source chart. Each daily use value divides the printed monthly use by the calendar days in that month.

Before and after electricity-bill graphic

$0$25$50$75$100$125Before solarAfter solar
The source's two average-bill bars were not individually labeled. This drawing preserves their relative original heights.

Source cumulative utility-bill savings

$0$2,500$5,000$7,500$10,000$12,500$15,000$17,50015101520Year 20: $16,166Years in source model
The five bars preserve the source geometry. Only the 20-year amount was labeled in the source. This is a forecast, not actual savings.
Pool house: every printed first-year model value
MonthSolar generation (kWh)Estimated use (kWh)Bill beforeBill afterEstimated savings
Jan266691$105$78$27
Feb354617$97$62$35
Mar591513$86$40$46
Apr744455$80$35$45
May820452$80$33$47
Jun818592$95$36$58
Jul1,009723$108$39$69
Aug847724$108$43$65
Sep671651$101$46$55
Oct654506$86$37$49
Nov405467$82$45$37
Dec316608$96$65$32
Sum of rounded source months7,4956,999$1,124$559$565

The pool-house quote is described as stand-alone without grid tie. Its worksheet nonetheless compares hypothetical utility bills and includes a fixed residential charge in the model. The $16,166 long-term chart is a scenario, not a verified utility saving, power guarantee or cost of an actual separately metered account. A timing-based load and battery study would still be needed.

How should you compare the numbers?

Both archived models assumed about $0.10 per kWh usage, a $33 fixed charge, 4% annual utility price growth, and the source's System Advisor Model settings. They do not show exact imported or exported kWh separately. Manufacturer warranty literature and the quote were historical; they do not establish current eligibility, product registration or installed performance. The main-house quotes presented old hypothetical incentive subtractions, not actual net prices or proof of eligibility. The documented gross options here remain separate and are not combined into an amount paid.

The file does not verify acceptance, payment, utility approval, installation or meter data. It contains no customer identifiers here.

Compare solar designs for your buildings

Source: Anonymized 19-page The Metal Roofers property proposal packet. Main-house model and quotes, pp. 6–11; equipment literature, pp. 12–14; pool-house model and quote, pp. 15–19. Rounded source values reproduced with sums labeled; all charts are estimates.