Cedar Hill, Tennessee · Two historical options for the same site

Two Cedar Hill solar proposals: 52 or 84 panels on one property

One property had two solar estimates: $84,240 for a 52-panel design, or $166,110 for an 84-panel design with three batteries. The projects used the same assumed electricity baseline but different hardware and layouts, so the price difference was not simply for 32 more panels.

52 versus 84 Jinko 540 W modules
28.08 versus 45.36 kW DC
Gross proposed prices, no paid invoices verified
$84,240 versus $166,110
Three batteries specified only on the larger design
42.9 kWh listed

What changed from the 52-panel to the 84-panel option?

Both September 2025 estimates specify JinkoSolar JKM540M-72HL4-V modules at 540 W each. Final equipment locations and the mounting approach were subject to the site walk.

Two modeled configurations for one customer site
Feature52-panel option84-panel option
Array size52 × 540 W = 28.08 kW DC84 × 540 W = 45.36 kW DC
Conversion equipmentEnphase IQ8X-80-M-DOM-US microinverters. The text lists 60 while also saying one per module; the count needs correction or confirmation.Three EG4 FlexBOSS21 hybrid inverters
StorageNo batteries specified in this estimate.Three EG4 PowerPro WallMount units, 14.3 kWh each and 42.9 kWh total as listed.
Modeled orientation26 modules at 271° and 26 at 91°, both 20° slope.42 modules at 271° and 42 at 91°, both 15° slope.
Gross price$84,240$166,110
Approximate annual energy ratio in the model68% reported108% reported

Each scope covered its listed mounting hardware, electrical integration, app/monitoring onboarding and commissioning, which were proposed activities. The estimates contain historical incentive examples. Their gross costs are shown before any incentive; no tax benefit or accepted purchase is implied.

How did the 52-panel energy and bill model change by month?

This model uses 48,040 kWh estimated annual consumption, a location-based $0.10/kWh energy charge and a $33.00 monthly fixed charge. The invoice for actual electricity use was not verified.

Monthly model for the 52-panel proposal
MonthDaily PV (kWh/day)PV output (kWh)Baseline use (kWh)Bill beforeBill afterPrinted savings
Jan39.31,2196,480$707$594$112
Feb59.31,6615,840$640$493$147
Mar84.32,6124,360$486$328$159
Apr1093,2602,680$312$186$125
May1163,5902,560$299$169$130
Jun1203,5943,680$416$235$181
Jul1414,3635,120$565$322$244
Aug1153,5644,680$520$310$210
Sep95.82,8753,160$362$228$134
Oct922,8522,320$274$181$94
Nov58.91,7662,080$249$176$73
Dec46.81,4505,080$561$441$120
Sum of rounded rowsNot additive32,80648,040$5,391$3,663$1,729

The printed $50,535 lifetime bill savings is estimated, not actual. The model used 13.1% total loss and 3.2% inverter loss; those assumptions do not establish how the finished roof or ground array would have performed.

What did the larger array model show?

The 84-panel option uses the same 48,040 kWh baseline. The rounded production rows add to 51,758 kWh, compared with 32,806 kWh in the smaller option. That does not imply the home uses every additional kWh or that electricity costs fall in the same proportion.

Monthly model for the 84-panel proposal
MonthDaily PV (kWh/day)PV output (kWh)Baseline use (kWh)Bill beforeBill afterPrinted savings
Jan61.71,9146,480$707$524$182
Feb93.12,6075,840$640$402$238
Mar1334,1284,360$486$220$267
Apr1725,1752,680$312$79$233
May1845,6922,560$299$58$241
Jun1905,6873,680$416$122$294
Jul2236,9065,120$565$200$365
Aug1815,6164,680$520$193$327
Sep1514,5223,160$362$123$238
Oct1454,4822,320$274$77$197
Nov922,7602,080$249$85$164
Dec73.22,2695,080$561$353$208
Sum of rounded rowsNot additive51,75848,040$5,391$2,436$2,954

The model used 16.2% total loss and 3.1% inverter loss and reports $86,751 estimated lifetime bill savings. Printed dollar columns round separately, so differences need not match the savings column exactly. The lifetime chart does not tabulate every year; no unlabeled values have been inferred.

What had to be confirmed before selecting either option?

These are two options for one property, not two installations. Confirm mounting and layout, the unverified microinverter count on the smaller design, the electrical scope and usable battery backup for the larger design, and the utility's actual treatment of imports and exports.

Neither file is an executed contract. No paid invoice, chosen option, project photo, commissioned array, metered output, offset, or backup result was verified.

Compare two quotes using the same electricity baseline

Ask each installer for the panel count and inverter schedule, the specific equipment included in storage and the monthly model with a common rate assumption.

Ask about a solar design comparison

Source: Anonymized The Metal Roofers September 10, 2025 52- and 84-panel estimate files, equipment, gross pricing and both performance appendices.