Brentwood, Tennessee · Historical Tesla solar and battery proposal

A Brentwood solar proposal with six Tesla storage units and a Gateway

A September 2025 Brentwood estimate paired 59 rooftop solar modules in the modeled layout with three Tesla Powerwall 3 units, three expansion units and Tesla Gateway hardware. The printed quote total was $109,850. A separate memo used a different price, and the home's modeled electricity use was not consistent across the file.

59 × 425 W modules; about 25.1 kW in the quote
25.075 kW DC
Three main Powerwall 3 units plus three expansions
81.0 kWh listed
Original total line, not a confirmed accepted or paid price
$109,850 quoted

What equipment and work did the estimate describe?

The detailed equipment schedule, rather than the generic introduction, identifies the number of battery units. No quote or attached product datasheet establishes what was eventually installed.

Proposed equipment and scope
ItemDocumented proposal detail
Solar array59 JinkoSolar JKM425N-54HL4 modules at 425 W, for 25.075 kW DC. Reported estimated annual PV output: 30,997 kWh.
Array model17 modules at 130°, 23 at 40°, and 19 at 220° azimuth, all at 33° slope. Final mounting schedule and field layout to be confirmed.
Tesla storageThree Powerwall 3 main units, each with an integrated inverter, plus three Powerwall 3 Expansion units. The quote lists roughly 81.0 kWh combined. No verified outage runtime or usable reserve under load.
Backup controlsTesla Backup Gateway hardware as needed to manage switchover, metering and monitoring. No exact Gateway model was finalized in the quoted scope.
Electrical and workmanshipMounting hardware, integration, app setup, commissioning and basic testing were proposed. The estimate described a two-year limited workmanship term, separate from product warranties.
Gross total line$109,850. No signed acceptance, change order, paid invoice or verified commissioning paperwork accompanies this estimate.

A historical incentive illustration elsewhere starts from $134,925, which conflicts with the $109,850 total line. The quote does not reconcile the two figures. No tax benefit, net price or accepted final price is shown.

What does the monthly forecast actually say?

The model includes a table of estimated month-by-month generation, assumed electricity use, imports, exports, export credit, and utility bills. The amounts below are the printed rows, not meter data or bills received.

Source table with exact rounded monthly figures
MonthAverage daily PV (kWh/day)PV output (kWh)Assumed use (kWh)Grid imports (kWh)Exports (kWh)Export creditBill beforeBill afterPrinted savings
Jan47.11,4591,47518811$0$179$40$139
Feb691,9321,3180514$9$162$18$144
Mar842,6051,09501,429$26$138$18$120
Apr1033,08997202,053$37$123$18$104
May1073,31396402,291$41$122$18$104
Jun1233,6841,26502,350$42$161$18$142
Jul1153,5521,54401,920$35$192$18$173
Aug1083,3461,54501,703$31$192$18$173
Sep87.12,6121,38981,136$20$174$18$156
Oct78.32,4281,08001,273$23$134$18$116
Nov54.61,6379970553$10$125$18$107
Dec43.21,3401,297218244$4$160$39$120
Sum of rowsNot additive30,99714,94141415,477$278$1,862$259$1,598

The bill figures and savings are independently rounded in the model. The separately printed $48,865 lifetime savings is also modeled, not a customer outcome; the long-term chart does not print every single annual value.

Why don’t we quote this as 207% actual offset?

The document advertises 207% in its model, but the monthly table totals 14,941 kWh assumed consumption while another narrative says 40,000 kWh. The exact same 30,997 kWh production would compare very differently against those two baselines. Neither is proof of the property's actual consumption or bill savings.

The historical model lists an assumed location-based residential rate, not an account-confirmed tariff. It cites the System Advisor Model 2020.02.29.r2, 15.2% system loss, and 2.5% inverter loss. Even the consistent monthly rows document a scenario, not energy delivered or sold.

No independent permission to operate, measured annual production, payment, finalized equipment, project photo or operating result was verified. The system cannot be represented as complete, paid or performing as forecast.

Ask for a verified backup and solar design

Bring your actual electricity usage and the circuits you want to keep running. Ask for a consistent usage baseline across the estimate, a final Gateway model, and a clear distinction between nominal storage and usable backup.

Request a Brentwood solar and battery assessment

Source: Anonymized The Metal Roofers September 9, 2025 solar and Powerwall/Gateway estimate and its attached model. Historical proposal only.